Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
791
matching recommendationsNAICS | 33131 | Alumina and Aluminum Production and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0272 # 04 Y:2008 | 04 | 2008 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $17,652 | $6,200 | Not Implemented |
LE0272 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,361 | $272 | Implemented |
LE0272 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $2,647 | $480 | Not Implemented |
LE0272 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,150 | $92,543 | Not Implemented |
LE0271 # 01 Y:2008 | 01 | 2008 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $94,198 | $45,000 | Implemented |
LE0271 # 02 Y:2008 | 02 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $35,042 | $875 | Not Implemented |
LE0271 # 03 Y:2008 | 03 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,263 | $40,000 | Not Implemented |
LE0271 # 04 Y:2008 | 04 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $17,604 | $3,900 | Not Implemented |
LE0271 # 05 Y:2008 | 05 | 2008 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,909 | $30,000 | Not Implemented |
LE0271 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,337 | $3,000 | Implemented |
LE0271 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,931 | $1,000 | Not Implemented |
LE0271 # 08 Y:2008 | 08 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $5,095 | $7,278 | Not Implemented |
LE0271 # 09 Y:2008 | 09 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,934 | $1,000 | Implemented |
LE0271 # 10 Y:2008 | 10 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,865 | $150 | Not Implemented |
LE0271 # 11 Y:2008 | 11 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $804 | $500 | Not Implemented |
LE0271 # 12 Y:2008 | 12 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $704 | $255 | Not Implemented |
LE0271 # 13 Y:2008 | 13 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,736 | $54,562 | Not Implemented |
GT0848 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,250 | $19,500 | Not Implemented |
GT0848 # 02 Y:2008 | 02 | 2008 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $180,800 | $541,073 | Not Implemented |
GT0848 # 03 Y:2008 | 03 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $340 | $1,000 | Implemented |
GT0848 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,718 | $3,250 | Implemented |
GT0848 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,088 | $0 | Implemented |
GT0848 # 06 Y:2008 | 06 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,164 | $10,000 | Not Implemented |
UA0016 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $60,322 | $10,000 | Implemented |
UA0016 # 02 Y:2008 | 02 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $22,023 | $20,000 | Not Implemented |