Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

193

matching recommendations
Reset
NAICS 331314 Secondary Smelting and Alloying of Aluminum
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0378 # 04 Y:2010 04 2010 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $102 $10 Not Implemented
UM0378 # 05 Y:2010 05 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $68,485 $2,000 Implemented
UM0378 # 06 Y:2010 06 2010 RECOVER WASTE HEAT FROM EQUIPMENT $3,599 $1,500 Implemented
UM0378 # 07 Y:2010 07 2010 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $3,345 $7,800 Implemented
LE0306 # 01 Y:2010 01 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $75,618 $68,000 Not Implemented
LE0306 # 02 Y:2010 02 2010 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,392 $12,700 Not Implemented
LE0306 # 03 Y:2010 03 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,691 $10,000 Not Implemented
LE0306 # 04 Y:2010 04 2010 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,549 $1,800 Not Implemented
NC0392 # 01 Y:2009 01 2009 $21,004 $50,000 Implemented
NC0392 # 02 Y:2009 02 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $74,466 $220,000 Not Implemented
NC0392 # 03 Y:2009 03 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,152 $23,000 Not Implemented
NC0392 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,938 $4,825 Not Implemented
NC0392 # 05 Y:2009 05 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $315 $100 Implemented
NC0392 # 06 Y:2009 06 2009 DEVELOP A REPAIR/REPLACE POLICY $2,139 $3,888 Not Implemented
NC0392 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,657 $33,097 Implemented
NC0392 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $186 $577 Implemented
MZ0037 # 01 Y:2009 01 2009 PREHEAT COMBUSTION AIR WITH WASTE HEAT $87,552 $18,000 Not Implemented
MZ0037 # 02 Y:2009 02 2009 USE OPTIMUM THICKNESS INSULATION $1,717 $4,200 Not Implemented
MZ0037 # 03 Y:2009 03 2009 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $11,665 $2,900 Not Implemented
MZ0037 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $739 $850 Not Implemented
MZ0037 # 05 Y:2009 05 2009 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $710 $1,993 Not Implemented
MZ0037 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40,988 $59,705 Not Implemented
MZ0037 # 07 Y:2009 07 2009 INSTALL OCCUPANCY SENSORS $490 $640 Not Implemented
UD0774 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $118,235 $50,000 Not Implemented
UD0774 # 02 Y:2008 02 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $94,656 $6,000 Implemented