Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,045
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0312 # 12 Y:2005 | 12 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,062 | $101,583 | Not Implemented |
SF0312 # 13 Y:2005 | 13 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,414 | $27,090 | Implemented |
WV0320 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,626 | $30,000 | Implemented |
WV0320 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,978 | $5,805 | Implemented |
WV0320 # 03 Y:2005 | 03 | 2005 | BURN WASTE OIL FOR HEAT | $4,770 | $4,000 | Not Implemented |
WV0320 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $4,359 | $4,750 | Implemented |
WV0320 # 05 Y:2005 | 05 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,094 | $2,700 | Implemented |
WV0320 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,232 | $0 | Not Implemented |
WV0320 # 07 Y:2005 | 07 | 2005 | USE COMPRESSOR AIR FILTERS | $2,183 | $800 | Not Implemented |
WV0320 # 16 Y:2005 | 16 | 2005 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $351 | $26 | Not Implemented |
WV0320 # 15 Y:2005 | 15 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $438 | $80 | Implemented |
WV0320 # 14 Y:2005 | 14 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $457 | $430 | Implemented |
WV0320 # 13 Y:2005 | 13 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $474 | $488 | Not Implemented |
WV0320 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $487 | $400 | Not Implemented |
WV0320 # 11 Y:2005 | 11 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $728 | $667 | Implemented |
WV0320 # 10 Y:2005 | 10 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $975 | $955 | Not Implemented |
WV0320 # 09 Y:2005 | 09 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,621 | $213 | Implemented |
WV0320 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,732 | $1,645 | Implemented |
LE0214 # 01 Y:2005 | 01 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,742 | $30,000 | Not Implemented |
LE0214 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,637 | $5,500 | Implemented |
LE0214 # 03 Y:2005 | 03 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,017 | $320 | Implemented |
LE0214 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,291 | $640 | Not Implemented |
LE0214 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,259 | $2,300 | Implemented |
LE0214 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,575 | $500 | Implemented |
WI0493 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,163 | $49,680 | Not Implemented |