Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,045

matching recommendations
Reset
NAICS 3315 Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0437 # 03 Y:2003 03 2003 INSTALL TIMERS AND/OR THERMOSTATS $17,126 $3,000 Not Implemented
WI0437 # 04 Y:2003 04 2003 INSTALL AUTOMATIC STACK DAMPER $16,313 $1,500 Not Implemented
WI0437 # 05 Y:2003 05 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $9,938 $8,555 Not Implemented
BD0227 # 01 Y:2003 01 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,980 $3,000 Not Implemented
BD0227 # 02 Y:2003 02 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,495 $0 Implemented
BD0227 # 03 Y:2003 03 2003 USE RADIANT HEATER FOR SPOT HEATING $4,490 $7,000 Implemented
BD0227 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $2,617 $450 Implemented
BD0227 # 05 Y:2003 05 2003 RECOVER AND REUSE COOLING WATER $31,410 $7,500 Not Implemented
BD0227 # 06 Y:2003 06 2003 MINIMIZE WATER USAGE $17,898 $0 Not Implemented
BD0227 # 07 Y:2003 07 2003 CONTRACT A WOOD PALLET RECYCLING COMPANY $11,250 $1,000 Implemented
BD0226 # 01 Y:2003 01 2003 USE RADIANT HEATER FOR SPOT HEATING $17,147 $11,000 Not Implemented
BD0226 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,838 $1,200 Implemented
BD0226 # 03 Y:2003 03 2003 USE SYNTHETIC LUBRICANT $1,169 $500 Not Implemented
BD0226 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $740 $0 Implemented
BD0226 # 05 Y:2003 05 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $545 $1,250 Implemented
BD0226 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $74 $290 Not Implemented
BD0226 # 07 Y:2003 07 2003 RECYCLE CASTING SAND $9,750 $1,000 Implemented
BD0226 # 08 Y:2003 08 2003 CONTRACT A WOOD PALLET RECYCLING COMPANY $28,125 $1,000 Implemented
BD0226 # 09 Y:2003 09 2003 AUTOMATE PAYROLL SYSTEM $25,480 $2,500 Implemented
LM0047 # 01 Y:2003 01 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,457 $6,432 Not Implemented
LM0047 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,703 $200 Implemented
LM0047 # 03 Y:2003 03 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $997 $228 Implemented
LM0047 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $370 $525 Implemented
LM0047 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $837 $1,365 Not Implemented
LM0047 # 06 Y:2003 06 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,158 $1,222 Not Implemented