Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

468

matching recommendations
Reset
NAICS 331523 Nonferrous Metal Die-Casting Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UMS004 # 05 Y:2012 05 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,500 $0 Not Implemented
UMS004 # 06 Y:2012 06 2012 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $40,000 $40,000 Not Implemented
UMS004 # 07 Y:2012 07 2012 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $1,300 $0 Not Implemented
UA3015 # 01 Y:2011 01 2011 REPAIR OR REPLACE STEAM TRAPS $1,604 $3,770 Implemented
UA3015 # 02 Y:2011 02 2011 REPAIR AND ELIMINATE STEAM LEAKS $3,000 $1,280 Implemented
UA3015 # 03 Y:2011 03 2011 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $3,571 $2,440 Implemented
UA3015 # 04 Y:2011 04 2011 INSULATE BARE EQUIPMENT $2,745 $8,121 Not Implemented
UA3015 # 05 Y:2011 05 2011 COVER OPEN TANKS $3,038 $300 Not Implemented
SD0412 # 01 Y:2009 01 2009 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $41,473 $350,000 Not Implemented
SD0412 # 02 Y:2009 02 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $21,022 $10,000 Not Implemented
SD0412 # 03 Y:2009 03 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,233 $13,039 Implemented
SD0412 # 04 Y:2009 04 2009 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $13,730 $70,000 Not Implemented
SD0412 # 05 Y:2009 05 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,333 $0 Implemented
SD0412 # 06 Y:2009 06 2009 INSTALL SKYLIGHTS $3,365 $9,170 Implemented
TT0026 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,300 $63,800 Not Implemented
TT0026 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,980 $6,600 Not Implemented
TT0026 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,430 $3,640 Not Implemented
TT0026 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $590 Not Implemented
TT0026 # 05 Y:2008 05 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,119 $55,000 Not Implemented
TT0026 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,000 $4,900 Not Implemented
TT0026 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $25,000 $1,000 Not Implemented
TT0026 # 08 Y:2008 08 2008 OPTIMIZE PLANT POWER FACTOR $1,150 $6,000 Not Implemented
IA0422 # 01 Y:2008 01 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,946 $660 Implemented
IA0422 # 02 Y:2008 02 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,525 $15 Implemented
IA0422 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,191 $300 Implemented