Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
393
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0228 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $31,676 | $40,711 | Implemented |
SU0228 # 03 Y:2006 | 03 | 2006 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $39,585 | $111,774 | Implemented |
SU0228 # 04 Y:2006 | 04 | 2006 | INCREASE USE OF AUTOMATION | $1,765,875 | $3,500,000 | Implemented |
SU0216 # 01 Y:2005 | 01 | 2005 | UPGRADE OBSOLETE EQUIPMENT | $3,046 | $0 | Not Implemented |
SU0216 # 02 Y:2005 | 02 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $103 | $0 | Implemented |
SU0216 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $294 | Implemented |
SU0216 # 04 Y:2005 | 04 | 2005 | USE SYNTHETIC LUBRICANT | $193 | $300 | Implemented |
SU0216 # 05 Y:2005 | 05 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $60,060 | $134,400 | Implemented |
SU0216 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $981 | Implemented |
SU0216 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,140 | $3,550 | Not Implemented |
SU0216 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,013 | $17,360 | Implemented |
SU0216 # 09 Y:2005 | 09 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $389 | $1,520 | Not Implemented |
SU0166 # 01 Y:2003 | 01 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,012 | $232 | Not Implemented |
SU0166 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,388 | $480 | Not Implemented |
SU0166 # 03 Y:2003 | 03 | 2003 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $28,125 | $10,016 | Implemented |
SU0166 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,270 | $24,797 | Not Implemented |
SU0166 # 05 Y:2003 | 05 | 2003 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $24,000 | $19,912 | Not Implemented |
SU0166 # 06 Y:2003 | 06 | 2003 | USE EXISTING DAM TO GENERATE ELECTRICITY | $49,025 | $132,000 | Not Implemented |
SU0166 # 07 Y:2003 | 07 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,000 | $68,560 | Implemented |
SU0165 # 01 Y:2003 | 01 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $99,450 | $110,400 | Implemented |
SU0165 # 02 Y:2003 | 02 | 2003 | RECOVER AND REUSE SPENT ACID BATHS | $30,138 | $3,234 | Implemented |
SU0165 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,370 | $17,064 | Implemented |
SU0165 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,503 | $937 | Implemented |
SU0165 # 05 Y:2003 | 05 | 2003 | OPTIMIZE PLANT POWER FACTOR | $9,177 | $20,736 | Not Implemented |
SU0165 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,763 | $5,538 | Not Implemented |