Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0323 # 05 Y:2005 | 05 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,033 | $1,200 | Not Implemented |
WV0323 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,015 | $0 | Not Implemented |
WV0323 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $869 | $990 | Not Implemented |
WV0323 # 08 Y:2005 | 08 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $698 | $260 | Not Implemented |
WV0323 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $613 | $250 | Not Implemented |
WV0323 # 10 Y:2005 | 10 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $600 | $40 | Not Implemented |
WV0323 # 11 Y:2005 | 11 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $553 | $1,108 | Not Implemented |
WV0323 # 12 Y:2005 | 12 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $436 | $715 | Not Implemented |
WV0323 # 13 Y:2005 | 13 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $428 | $140 | Not Implemented |
WV0323 # 14 Y:2005 | 14 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $197 | $138 | Not Implemented |
IA0370 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,763 | $1,492 | Implemented |
IA0370 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,415 | $45 | Not Implemented |
IA0370 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,432 | $955 | Not Implemented |
IA0370 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,500 | $20,993 | Implemented |
IA0370 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $738 | $1,792 | Not Implemented |
IA0370 # 06 Y:2005 | 06 | 2005 | DISCONNECT BALLASTS | $1,208 | $1,260 | Not Implemented |
IA0370 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,192 | $0 | Implemented |
IA0370 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $4,488 | $4,081 | Not Implemented |
IA0370 # 09 Y:2005 | 09 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,049 | $5,655 | Not Implemented |
IA0370 # 10 Y:2005 | 10 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,492 | $9,397 | Not Implemented |
TA0100 # 01 Y:2005 | 01 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $136,425 | $38,485 | Not Implemented |
TA0100 # 02 Y:2005 | 02 | 2005 | INSULATE BARE EQUIPMENT | $15,690 | $1,015 | Implemented |
TA0100 # 03 Y:2005 | 03 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,111 | $7,705 | Not Implemented |
TA0100 # 04 Y:2005 | 04 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,280 | $1,485 | Not Implemented |
TA0100 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,925 | $205 | Implemented |