IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,344

matching recommendations
Reset
NAICS 332 Fabricated Metal Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0090 # 03 Y:2005 03 2005 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $2,100 $0 Not Implemented
LM0090 # 04 Y:2005 04 2005 $2,898 $2,000 Not Implemented
LM0090 # 05 Y:2005 05 2005 $45,000 $32,440 Not Implemented
LM0090 # 06 Y:2005 06 2005 $24,485 $2,000 Not Implemented
LM0090 # 07 Y:2005 07 2005 INSTALL SKYLIGHTS $2,790 $7,500 Not Implemented
AM0481 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,470 $70,240 n/a
AM0481 # 02 Y:2005 02 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,990 $600 Implemented
AM0481 # 03 Y:2005 03 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $745 $0 Implemented
AM0481 # 04 Y:2005 04 2005 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $355 $528 Implemented
AM0481 # 05 Y:2005 05 2005 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $54,010 $1,050 Not Implemented
AM0481 # 06 Y:2005 06 2005 REUSE RAGS UNTIL COMPLETELY SOILED $200 $100 Implemented
AM0481 # 07 Y:2005 07 2005 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $125 $20 Not Implemented
LE0205 # 01 Y:2005 01 2005 $65,962 $35,000 Implemented
LE0205 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,462 $15,000 Not Implemented
LE0205 # 03 Y:2005 03 2005 OPTIMIZE PLANT POWER FACTOR $4,673 $5,050 Not Implemented
LE0205 # 04 Y:2005 04 2005 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,294 $2,500 Implemented
LE0205 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $1,527 $300 Not Implemented
LE0205 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,521 $150 Implemented
UM0274 # 01 Y:2005 01 2005 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $42,936 $135,000 Not Implemented
UM0274 # 02 Y:2005 02 2005 RECOVER WASTE HEAT FROM EQUIPMENT $5,622 $2,000 Not Implemented
UM0274 # 03 Y:2005 03 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,242 $0 Implemented
UM0274 # 04 Y:2005 04 2005 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,966 $200 Not Implemented
UM0274 # 05 Y:2005 05 2005 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,699 $700 Not Implemented
UM0274 # 06 Y:2005 06 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $791 $2,000 Not Implemented
AM0480 # 01 Y:2005 01 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,010 $1,800 Implemented