Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,507
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0436 # 08 Y:2003 | 08 | 2003 | INSULATE BARE EQUIPMENT | $280 | $75 | Implemented |
AM0436 # 09 Y:2003 | 09 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $700 | $40 | Implemented |
AM0436 # 10 Y:2003 | 10 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $100 | $0 | Not Implemented |
MA0530 # 01 Y:2003 | 01 | 2003 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $233,841 | $25,050 | n/a |
MA0530 # 02 Y:2003 | 02 | 2003 | IMPROVE SPACE COMFORT CONDITIONING | $56,030 | $207,000 | n/a |
MA0530 # 03 Y:2003 | 03 | 2003 | CLEAR AND RENT EXISTING SPACE | $83,099 | $162,400 | Not Implemented |
MA0530 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,234 | $30,400 | n/a |
MA0530 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,046 | $9,100 | Not Implemented |
MA0530 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,396 | $9,900 | Not Implemented |
MA0530 # 07 Y:2003 | 07 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,661 | $400 | Implemented |
MA0530 # 08 Y:2003 | 08 | 2003 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $8,213 | $26,700 | Not Implemented |
MA0530 # 09 Y:2003 | 09 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,271 | $2,750 | Implemented |
MA0530 # 10 Y:2003 | 10 | 2003 | PAY BILLS ON TIME TO AVOID LATE FEES | $692 | $1,275 | Implemented |
AM0435 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,300 | $500 | Implemented |
AM0435 # 02 Y:2003 | 02 | 2003 | USE SYNTHETIC LUBRICANT | $12,740 | $0 | Not Implemented |
AM0435 # 03 Y:2003 | 03 | 2003 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $4,670 | $0 | Not Implemented |
AM0435 # 04 Y:2003 | 04 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,100 | $0 | Implemented |
AM0435 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $950 | $235 | Not Implemented |
AM0435 # 06 Y:2003 | 06 | 2003 | USE PHOTOCELL CONTROLS | $775 | $75 | Implemented |
WI0442 # 01 Y:2003 | 01 | 2003 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $188,665 | $146,300 | Not Implemented |
WI0442 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,332 | $6,498 | Not Implemented |
WI0442 # 03 Y:2003 | 03 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $5,132 | $0 | Not Implemented |
WI0442 # 04 Y:2003 | 04 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,640 | $10,000 | Not Implemented |
WI0442 # 05 Y:2003 | 05 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,559 | $500 | Not Implemented |
IC0057 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,372 | $9,932 | Not Implemented |