Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
948
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0949 # 07 Y:2016 | 07 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,996 | $57,770 | Implemented |
WV0527 # 09 Y:2016 | 09 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $581 | $1,275 | Implemented |
WV0527 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $13,053 | $54,000 | Not Implemented |
WV0527 # 02 Y:2016 | 02 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,539 | $1,100 | Implemented |
WV0527 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,268 | $2,530 | Implemented |
WV0527 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,255 | $6,300 | Not Implemented |
WV0527 # 05 Y:2016 | 05 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $2,540 | $4,500 | Not Implemented |
WV0527 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,524 | $60 | Implemented |
WV0527 # 07 Y:2016 | 07 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,189 | $283 | Not Implemented |
WV0527 # 08 Y:2016 | 08 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,044 | $165 | Implemented |
WV0527 # 10 Y:2016 | 10 | 2016 | INSULATE BARE EQUIPMENT | $252 | $263 | Implemented |
WV0527 # 11 Y:2016 | 11 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $212 | $527 | Implemented |
WV0526 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,991 | $180 | Implemented |
WV0526 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,798 | $78,534 | Implemented |
WV0526 # 02 Y:2016 | 02 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $24,527 | $35,260 | Implemented |
WV0526 # 04 Y:2016 | 04 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $1,872 | $1,122 | Implemented |
WV0526 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,676 | $3,122 | Not Implemented |
WV0526 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,654 | $46 | Implemented |
UD0945 # 01 Y:2016 | 01 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $5,063 | $8,000 | Implemented |
UD0945 # 02 Y:2016 | 02 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $527 | $0 | Implemented |
UD0945 # 03 Y:2016 | 03 | 2016 | REDUCE FLUID FLOW RATES | $7,163 | $0 | Implemented |
UD0945 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $623 | $30 | Implemented |
UD0945 # 05 Y:2016 | 05 | 2016 | REDUCE VENTILATION AIR | $77,225 | $18,850 | Not Implemented |
UD0945 # 06 Y:2016 | 06 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,486 | $8,972 | Not Implemented |
UD0945 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,610 | $0 | Not Implemented |