Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,062
matching recommendationsNAICS | 3321 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0819 # 06 Y:2010 | 06 | 2010 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,479 | $1,000 | Not Implemented |
UD0819 # 07 Y:2010 | 07 | 2010 | USE OPTIMUM THICKNESS INSULATION | $33,608 | $35,440 | Not Implemented |
UD0819 # 08 Y:2010 | 08 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $22,346 | $44,693 | Not Implemented |
UD0819 # 09 Y:2010 | 09 | 2010 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $11,925 | $7,032 | Not Implemented |
UD0819 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $6,484 | $6,000 | Not Implemented |
UD0819 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM TEMPERATURE | $3,080 | $6,160 | Not Implemented |
UD0819 # 12 Y:2010 | 12 | 2010 | USE OPTIMUM TEMPERATURE | $492 | $25 | Not Implemented |
UD0819 # 13 Y:2010 | 13 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,008 | $6,000 | Not Implemented |
UD0806 # 01 Y:2009 | 01 | 2009 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $169,364 | $0 | Implemented |
UD0806 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $75,878 | $0 | Implemented |
UD0806 # 03 Y:2009 | 03 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,287 | $157,500 | Not Implemented |
UD0806 # 04 Y:2009 | 04 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $29,959 | $10,000 | Not Implemented |
UD0806 # 05 Y:2009 | 05 | 2009 | COVER OPEN TANKS | $11,513 | $5,220 | Not Implemented |
UD0806 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $10,900 | $5,010 | Not Implemented |
UD0806 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,909 | $17,420 | Implemented |
UD0806 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $8,238 | $64,000 | Not Implemented |
UD0806 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,111 | $12,665 | Implemented |
UD0806 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,025 | $3,000 | Not Implemented |
UD0806 # 11 Y:2009 | 11 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,165 | $11,747 | Not Implemented |
UD0806 # 12 Y:2009 | 12 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,652 | $990 | Implemented |
UD0806 # 13 Y:2009 | 13 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,419 | $748 | Not Implemented |
UD0806 # 14 Y:2009 | 14 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,400 | $6,174 | Implemented |
UD0806 # 15 Y:2009 | 15 | 2009 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $2,991 | $15,000 | Not Implemented |
UD0806 # 16 Y:2009 | 16 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,636 | $4,000 | Not Implemented |
UD0806 # 17 Y:2009 | 17 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,995 | $0 | Implemented |