Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
208
matching recommendationsNAICS | 332119 | Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0489 # 07 Y:2014 | 07 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,213 | $2,425 | Implemented |
WV0489 # 05 Y:2014 | 05 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,585 | $0 | Implemented |
WV0489 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,622 | $6,539 | Implemented |
WV0489 # 03 Y:2014 | 03 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,336 | $0 | Implemented |
SU0341 # 01 Y:2013 | 01 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $357 | $0 | Implemented |
SU0341 # 02 Y:2013 | 02 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $314 | $0 | Implemented |
SU0341 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $299 | $0 | Implemented |
SU0341 # 05 Y:2013 | 05 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $626 | $137 | Implemented |
SD0464 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,895 | $27,250 | Implemented |
UK1212 # 11 Y:2012 | 11 | 2012 | PAY UTILITY BILLS ON TIME | $1,535 | $0 | Implemented |
UK1212 # 05 Y:2012 | 05 | 2012 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $4,209 | $3,430 | Implemented |
UK1212 # 04 Y:2012 | 04 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,314 | $2,240 | Implemented |
UK1212 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,414 | $26,320 | Implemented |
MZ0096 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $57,095 | $67,348 | Implemented |
MZ0096 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,732 | $29,201 | Implemented |
MZ0096 # 05 Y:2012 | 05 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $11,800 | $22,100 | Implemented |
MZ0096 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,395 | $5,400 | Implemented |
MZ0096 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $896 | $221 | Implemented |
MZ0096 # 09 Y:2012 | 09 | 2012 | USE PHOTOCELL CONTROLS | $507 | $560 | Implemented |
MZ0096 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $455 | $480 | Implemented |
MZ0096 # 11 Y:2012 | 11 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $467 | $480 | Implemented |
UD0858 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,006 | $500 | Implemented |
UD0858 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $1,000 | Implemented |
BD0403 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $10 | Implemented |
BD0403 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $851 | $450 | Implemented |