Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
274
matching recommendationsNAICS | 332216 | Saw Blade and Handtool Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0225 # 08 Y:2005 | 08 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,118 | $350 | Not Implemented |
LE0225 # 09 Y:2005 | 09 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,090 | $35,595 | Implemented |
UF0356 # 01 Y:2005 | 01 | 2005 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $0 | $150,000 | Not Implemented |
UF0356 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,843 | $21,108 | Implemented |
UF0356 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,348 | $2,000 | Implemented |
UF0356 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,008 | $700 | Implemented |
UF0356 # 05 Y:2005 | 05 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,918 | $1,185 | Not Implemented |
UF0356 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,295 | $2,194 | Implemented |
UF0356 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,232 | $1,450 | Implemented |
UF0356 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $96 | $245 | Implemented |
UF0356 # 09 Y:2005 | 09 | 2005 | RECYCLE FLUORESCENT LAMPS | $0 | $3,496 | Implemented |
WV0298 # 01 Y:2004 | 01 | 2004 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $3,459 | $2,100 | Not Implemented |
WV0298 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,929 | $440 | Implemented |
WV0298 # 03 Y:2004 | 03 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $2,864 | $1,928 | Not Implemented |
WV0298 # 04 Y:2004 | 04 | 2004 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,447 | $220 | Implemented |
WV0298 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $2,066 | $1,286 | Not Implemented |
WV0298 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,986 | $0 | Not Implemented |
WV0298 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,877 | $240 | Implemented |
WV0298 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,304 | $0 | Implemented |
WV0298 # 09 Y:2004 | 09 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $736 | $705 | Implemented |
WV0298 # 10 Y:2004 | 10 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $794 | $1,825 | Not Implemented |
WV0298 # 11 Y:2004 | 11 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $762 | $750 | Implemented |
WV0298 # 12 Y:2004 | 12 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $565 | $1,000 | Not Implemented |
WV0298 # 13 Y:2004 | 13 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $461 | $360 | Implemented |