Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,176
matching recommendationsNAICS | 3323 | Architectural and Structural Metals Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0370 # 08 Y:2014 | 08 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,133 | $15,100 | Not Implemented |
LE0370 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,137 | $6,750 | Not Implemented |
LE0370 # 10 Y:2014 | 10 | 2014 | REPLACE BOILER | $61,996 | $205,000 | Not Implemented |
LE0370 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,070 | $75,880 | Not Implemented |
BD0435 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,612 | $12,980 | Implemented |
BD0435 # 02 Y:2013 | 02 | 2013 | USE PHOTOCELL CONTROLS | $1,708 | $500 | Not Implemented |
BD0435 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $654 | $730 | Implemented |
BD0435 # 04 Y:2013 | 04 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $618 | $2,100 | Not Implemented |
BD0435 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $287 | $250 | Not Implemented |
IA0512 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,448 | $356 | Implemented |
IA0512 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,848 | $100 | Implemented |
IA0512 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,424 | $70 | Implemented |
IA0512 # 04 Y:2013 | 04 | 2013 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $629 | $890 | Not Implemented |
IA0512 # 05 Y:2013 | 05 | 2013 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $504 | $530 | Not Implemented |
IA0512 # 06 Y:2013 | 06 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $277 | $200 | Implemented |
IA0512 # 07 Y:2013 | 07 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $17,286 | $135,000 | Not Implemented |
UD0891 # 01 Y:2013 | 01 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $112,427 | $100,000 | Not Implemented |
UD0891 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,664 | $3,000 | Implemented |
UD0891 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,643 | $30,000 | Not Implemented |
UD0891 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $868 | $1,000 | Implemented |
UD0891 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,992 | $27,380 | Not Implemented |
UD0891 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $641 | $300 | Not Implemented |
IA0511 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,687 | $4,550 | Not Implemented |
IA0511 # 02 Y:2013 | 02 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,147 | $3,500 | Not Implemented |
IA0511 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,410 | $950 | Implemented |