IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,171

matching recommendations
Reset
NAICS 3323 Architectural and Structural Metals Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0469 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,900 $400 Implemented
AM0469 # 03 Y:2004 03 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,000 $0 Implemented
AM0469 # 04 Y:2004 04 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,460 $170 Implemented
AM0469 # 05 Y:2004 05 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $890 $0 Not Implemented
AM0469 # 06 Y:2004 06 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $340 $0 Implemented
AM0469 # 07 Y:2004 07 2004 USE SYNTHETIC LUBRICANT $260 $0 Not Implemented
MI0082 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $10,443 $96,600 Not Implemented
MI0082 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $10,385 $2,300 Implemented
MI0082 # 03 Y:2004 03 2004 INSTALL EQUIPMENT TO MOVE PRODUCT $47,434 $41,672 Not Implemented
MI0082 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,282 $2,670 Implemented
MI0082 # 05 Y:2004 05 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,313 $13,803 Not Implemented
MI0082 # 06 Y:2004 06 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,241 $610 Not Implemented
MI0082 # 07 Y:2004 07 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,594 $40 Not Implemented
LE0187 # 01 Y:2004 01 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $18,829 $10,000 Not Implemented
LE0187 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,995 $500 Implemented
LE0187 # 03 Y:2004 03 2004 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $5,383 $9,360 Not Implemented
LE0187 # 04 Y:2004 04 2004 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $4,271 $40,064 Not Implemented
LE0187 # 05 Y:2004 05 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,975 $15,000 Not Implemented
LE0187 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $921 $500 Implemented
LE0187 # 07 Y:2004 07 2004 USE SYNTHETIC LUBRICANT $810 $500 Not Implemented
WV0293 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,117 $20,400 Implemented
WV0293 # 02 Y:2004 02 2004 REDESIGN PROCESS $12,155 $10,080 Not Implemented
WV0293 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,541 $13,500 Implemented
WV0293 # 04 Y:2004 04 2004 DEVELOP A REPAIR/REPLACE POLICY $3,874 $1,250 Implemented
WV0293 # 05 Y:2004 05 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,283 $300 Not Implemented