Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsNAICS | 332312 | Fabricated Structural Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0435 # 02 Y:2013 | 02 | 2013 | USE PHOTOCELL CONTROLS | $1,708 | $500 | Not Implemented |
BD0435 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $654 | $730 | Implemented |
BD0435 # 04 Y:2013 | 04 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $618 | $2,100 | Not Implemented |
BD0435 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $287 | $250 | Not Implemented |
BD0435 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,612 | $12,980 | Implemented |
UD0891 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $641 | $300 | Not Implemented |
UD0891 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,992 | $27,380 | Not Implemented |
UD0891 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $868 | $1,000 | Implemented |
UD0891 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,643 | $30,000 | Not Implemented |
UD0891 # 02 Y:2013 | 02 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,664 | $3,000 | Implemented |
UD0891 # 01 Y:2013 | 01 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $112,427 | $100,000 | Not Implemented |
IA0511 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,687 | $4,550 | Not Implemented |
IA0511 # 02 Y:2013 | 02 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,147 | $3,500 | Not Implemented |
IA0511 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,410 | $950 | Implemented |
IA0511 # 04 Y:2013 | 04 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $466 | $1,291 | Implemented |
IA0511 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $186 | $35 | Implemented |
IA0500 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,461 | $210 | Implemented |
IA0500 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,004 | $710 | Implemented |
IA0500 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,170 | $105 | Not Implemented |
IA0500 # 03 Y:2013 | 03 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,050 | $2,500 | Not Implemented |
IA0500 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $413 | $1,388 | Implemented |
IA0500 # 05 Y:2013 | 05 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $19,132 | $8,000 | Not Implemented |
IA0500 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,973 | $1,700 | Implemented |
IA0500 # 07 Y:2013 | 07 | 2013 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $8,980 | $22,500 | Not Implemented |
IA0500 # 09 Y:2013 | 09 | 2013 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $280 | $110 | Not Implemented |