Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

48

matching recommendations
Reset
NAICS 33261 Spring and Wire Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0462 # 01 Y:2015 01 2015 REPAIR AND ELIMINATE STEAM LEAKS $3,033 $0 Implemented
SD0363 # 07 Y:2005 07 2005 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,445 $230 Not Implemented
SD0363 # 01 Y:2005 01 2005 INCREASE AMOUNT OF CONDENSATE RETURNED $9,477 $17,705 Not Implemented
SD0363 # 02 Y:2005 02 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,125 $9,250 Not Implemented
SD0363 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,335 $12,575 Not Implemented
SD0363 # 04 Y:2005 04 2005 INSULATE BARE EQUIPMENT $4,442 $8,400 Not Implemented
SD0363 # 05 Y:2005 05 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,107 $4,600 Not Implemented
SD0363 # 10 Y:2005 10 2005 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $10,056 $18,500 Not Implemented
SD0363 # 09 Y:2005 09 2005 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $229,203 $92,000 Not Implemented
SD0363 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,090 $31,655 Implemented
SD0363 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,580 $640 Not Implemented
SD0362 # 06 Y:2005 06 2005 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $194,956 $92,000 Not Implemented
SD0362 # 01 Y:2005 01 2005 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $41,074 $6,300 Implemented
SD0362 # 02 Y:2005 02 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $16,917 $0 Implemented
SD0362 # 03 Y:2005 03 2005 INSTALL OCCUPANCY SENSORS $14,251 $3,500 Implemented
SD0362 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,614 $26,000 Implemented
SD0362 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $749 $80 Implemented
SD0362 # 07 Y:2005 07 2005 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $8,160 $18,500 Not Implemented
SD0344 # 05 Y:2004 05 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,399 $18,500 Implemented
SD0344 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,104 $440 Implemented
SD0344 # 03 Y:2004 03 2004 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $8,464 $27,829 Not Implemented
SD0344 # 02 Y:2004 02 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $6,983 $7,700 Not Implemented
SD0344 # 01 Y:2004 01 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $42,981 $35,875 Implemented