Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
648
matching recommendationsNAICS | 332710 | Machine Shops |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0420 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $830 | $4,030 | Implemented |
SD0527 # 01 Y:2016 | 01 | 2016 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,997 | $600 | Not Implemented |
SD0527 # 02 Y:2016 | 02 | 2016 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $14,603 | $79,274 | Implemented |
SD0527 # 03 Y:2016 | 03 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $11,123 | $560 | Not Implemented |
SD0527 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,941 | $13,433 | Not Implemented |
SD0527 # 05 Y:2016 | 05 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,598 | $200 | Not Implemented |
SD0527 # 06 Y:2016 | 06 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,151 | $7,500 | Not Implemented |
SD0527 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,088 | $1,000 | Not Implemented |
SD0527 # 08 Y:2016 | 08 | 2016 | USE PHOTOCELL CONTROLS | $1,432 | $1,665 | Not Implemented |
SD0527 # 09 Y:2016 | 09 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $701 | $200 | Not Implemented |
SD0527 # 10 Y:2016 | 10 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $463 | $1,300 | Not Implemented |
AM0690 # 01 Y:2015 | 01 | 2015 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $17,950 | $12,830 | Not Implemented |
AM0690 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,320 | $2,000 | Not Implemented |
AM0690 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $14,550 | $31,640 | Not Implemented |
AM0690 # 04 Y:2015 | 04 | 2015 | OPTIMIZE PLANT POWER FACTOR | $11,210 | $21,860 | Not Implemented |
AM0690 # 05 Y:2015 | 05 | 2015 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,400 | $9,800 | Not Implemented |
AM0690 # 06 Y:2015 | 06 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,190 | $10,960 | Not Implemented |
AM0690 # 07 Y:2015 | 07 | 2015 | OPTIMIZE PLANT POWER FACTOR | $4,570 | $11,330 | Not Implemented |
AM0690 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $4,060 | $1,270 | Not Implemented |
AM0690 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,330 | $30 | Not Implemented |
LE0403 # 01 Y:2015 | 01 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $1,886 | $0 | Implemented |
LE0403 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,107 | $25 | Implemented |
LE0403 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $215 | $113 | Implemented |
LE0403 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,849 | $3,330 | Implemented |
LE0403 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $560 | $520 | Not Implemented |