Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
375
matching recommendationsNAICS | 332813 | Electroplating, Plating, Polishing, Anodizing, and Coloring |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0300 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $537 | $1,000 | Implemented |
UM0300 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $330 | $75 | Implemented |
UM0300 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,520 | $515 | Implemented |
UM0300 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,203 | $2,500 | Implemented |
UM0300 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $15,780 | $14,167 | Implemented |
SU0235 # 01 Y:2006 | 01 | 2006 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,295 | $0 | Implemented |
SU0235 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,954 | $0 | Implemented |
SU0235 # 03 Y:2006 | 03 | 2006 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $255 | $0 | Implemented |
SU0235 # 04 Y:2006 | 04 | 2006 | USE SYNTHETIC LUBRICANT | $247 | $0 | Implemented |
SU0235 # 05 Y:2006 | 05 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $14,219 | $1,527 | Implemented |
SU0235 # 06 Y:2006 | 06 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,179 | $25 | Implemented |
SU0235 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $42,734 | $6,467 | Implemented |
SU0235 # 08 Y:2006 | 08 | 2006 | INSULATE FEEDWATER TANK | $3,650 | $720 | Implemented |
SU0235 # 09 Y:2006 | 09 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,629 | $325 | Implemented |
SU0235 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,221 | $277 | Implemented |
SU0235 # 11 Y:2006 | 11 | 2006 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $22,111 | $5,932 | Implemented |
SU0235 # 13 Y:2006 | 13 | 2006 | KEEP BOILER TUBES CLEAN | $1,255 | $720 | Implemented |
LM0106 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $3,315 | $1,500 | Implemented |
MA0588 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $3,404 | $2,197 | Implemented |
MA0588 # 02 Y:2005 | 02 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $2,294 | $500 | Implemented |
MA0588 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,132 | $4,668 | Implemented |
MA0586 # 02 Y:2005 | 02 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,081 | $140 | Implemented |
MA0586 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,200 | $0 | Implemented |
MA0586 # 05 Y:2005 | 05 | 2005 | COMBINE UTILITY METERS | $1,736 | $1,950 | Implemented |
MA0586 # 06 Y:2005 | 06 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $841 | $1,646 | Implemented |