Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
159
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0930 # 05 Y:2015 | 05 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $43,664 | $10,000 | Not Implemented |
UD0930 # 04 Y:2015 | 04 | 2015 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $34,411 | $5,100 | Implemented |
UD0930 # 03 Y:2015 | 03 | 2015 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $2,426 | $300 | Not Implemented |
UD0930 # 02 Y:2015 | 02 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,352 | $0 | Implemented |
UD0930 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $59,188 | $0 | Implemented |
UD0927 # 07 Y:2015 | 07 | 2015 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $11,280 | $0 | Not Implemented |
UD0927 # 06 Y:2015 | 06 | 2015 | COMBINE UTILITY METERS | $63,547 | $50,000 | Not Implemented |
UD0927 # 05 Y:2015 | 05 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,750 | $3,000 | Not Implemented |
UD0927 # 04 Y:2015 | 04 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $11,905 | $0 | Not Implemented |
UD0927 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,022 | $300 | Implemented |
UD0927 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,206 | $1,000 | Not Implemented |
UD0927 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,025 | $0 | Implemented |
WV0469 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,550 | $4,036 | Implemented |
WV0469 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,090 | $1,989 | Implemented |
WV0469 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $21,317 | $6,300 | Not Implemented |
WV0469 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,896 | $10,694 | Not Implemented |
WV0469 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,996 | $0 | Implemented |
WV0469 # 05 Y:2013 | 05 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,853 | $5,700 | Not Implemented |
WV0469 # 06 Y:2013 | 06 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,514 | $1,000 | Implemented |
WV0469 # 08 Y:2013 | 08 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,484 | $2,292 | Not Implemented |
WV0469 # 11 Y:2013 | 11 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $314 | $56 | Implemented |
WV0469 # 12 Y:2013 | 12 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $77 | $281 | Not Implemented |
WV0469 # 10 Y:2013 | 10 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $706 | $460 | Not Implemented |
WV0469 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,378 | $70 | Implemented |
WV0423 # 09 Y:2011 | 09 | 2011 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $343 | $177 | Implemented |