Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,737
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0903 # 02 Y:2015 | 02 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $96,611 | $20,611 | Implemented |
OK0903 # 03 Y:2015 | 03 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $3,411 | $228 | Implemented |
OK0903 # 04 Y:2015 | 04 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,633 | $30,000 | Implemented |
OK0903 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,183 | $950 | Implemented |
OK0903 # 10 Y:2015 | 10 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,904 | $10,062 | Implemented |
MI0272 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $21,227 | $27,707 | Implemented |
MI0272 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $811 | $3,060 | Implemented |
MI0271 # 03 Y:2015 | 03 | 2015 | MINIMIZE WATER USAGE | $15,193 | $16,600 | Implemented |
MI0271 # 06 Y:2015 | 06 | 2015 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $4,265 | $11,000 | Implemented |
MI0271 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,369 | $4,590 | Implemented |
MI0271 # 11 Y:2015 | 11 | 2015 | INSTALL OCCUPANCY SENSORS | $956 | $373 | Implemented |
MI0270 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $29,534 | $20,088 | Implemented |
MI0270 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,500 | $80 | Implemented |
MI0270 # 04 Y:2015 | 04 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,676 | $3,600 | Implemented |
MI0270 # 06 Y:2015 | 06 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,773 | $2,040 | Implemented |
MI0270 # 07 Y:2015 | 07 | 2015 | USE OPTIMUM THICKNESS INSULATION | $3,506 | $1,140 | Implemented |
MI0270 # 08 Y:2015 | 08 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,926 | $7,869 | Implemented |
MI0270 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,546 | $5,294 | Implemented |
MI0270 # 12 Y:2015 | 12 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,467 | $1,660 | Implemented |
MI0270 # 15 Y:2015 | 15 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $970 | $80 | Implemented |
BD0455 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $19,322 | $13,700 | Implemented |
BD0455 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,997 | $40,950 | Implemented |
BD0455 # 05 Y:2015 | 05 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $7,295 | $25 | Implemented |
BD0455 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $6,580 | $2,250 | Implemented |
BD0455 # 08 Y:2015 | 08 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,994 | $900 | Implemented |