Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
292
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0678 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,836 | $10,835 | Implemented |
OK0678 # 04 Y:2004 | 04 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,162 | $800 | Implemented |
OK0678 # 05 Y:2004 | 05 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $22,602 | $28,350 | Not Implemented |
OK0678 # 06 Y:2004 | 06 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,188 | $12,597 | Not Implemented |
OK0678 # 07 Y:2004 | 07 | 2004 | INSTALL SET-BACK TIMERS | $3,347 | $2,200 | Implemented |
OK0678 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,847 | $14,078 | Not Implemented |
OK0678 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $546 | $1,154 | Implemented |
OK0678 # 10 Y:2004 | 10 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,985 | $0 | Not Implemented |
OK0689 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,021 | $1,180 | Not Implemented |
OK0689 # 02 Y:2004 | 02 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $857 | $0 | Not Implemented |
OK0689 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $1,079 | $2,156 | Implemented |
OK0689 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,433 | $252 | Implemented |
OK0689 # 05 Y:2004 | 05 | 2004 | INSTALL SET-BACK TIMERS | $853 | $822 | Not Implemented |
OK0689 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,521 | $472 | Not Implemented |
OK0689 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,393 | $758 | Not Implemented |
OK0675 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $274 | $256 | Implemented |
OK0675 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $124 | $231 | Not Implemented |
OK0675 # 03 Y:2003 | 03 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,171 | $2,000 | Implemented |
OK0675 # 04 Y:2003 | 04 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,210 | $2,000 | Not Implemented |
OK0675 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $565 | $367 | Implemented |
OK0675 # 06 Y:2003 | 06 | 2003 | OPTIMIZE PLANT POWER FACTOR | $428 | $2,730 | Not Implemented |
OK0675 # 07 Y:2003 | 07 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,672 | $2,173 | Not Implemented |
OK0675 # 08 Y:2003 | 08 | 2003 | INSTALL SET-BACK TIMERS | $1,993 | $0 | Not Implemented |
OK0675 # 09 Y:2003 | 09 | 2003 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $14,350 | $23,640 | Not Implemented |
OK0675 # 10 Y:2003 | 10 | 2003 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $61,378 | $3,000 | Not Implemented |