Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,345

matching recommendations
Reset
NAICS 333 Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0356 # 04 Y:2007 04 2007 BURN WASTE OIL FOR HEAT $4,096 $3,400 Not Implemented
WV0356 # 05 Y:2007 05 2007 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,275 $0 Not Implemented
WV0356 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,880 $0 Implemented
WV0356 # 07 Y:2007 07 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,349 $1,000 Implemented
WV0356 # 08 Y:2007 08 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,061 $1,000 Not Implemented
WV0356 # 09 Y:2007 09 2007 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $942 $1,100 Not Implemented
WV0356 # 10 Y:2007 10 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $855 $1,900 Implemented
WV0356 # 11 Y:2007 11 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $715 $350 Implemented
WV0356 # 12 Y:2007 12 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $697 $1,080 Implemented
WV0356 # 13 Y:2007 13 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $674 $155 Not Implemented
WV0356 # 14 Y:2007 14 2007 RECOVER WASTE HEAT FROM EQUIPMENT $587 $500 Not Implemented
WV0356 # 15 Y:2007 15 2007 DEVELOP A REPAIR/REPLACE POLICY $504 $270 Implemented
WV0356 # 16 Y:2007 16 2007 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $499 $280 Not Implemented
WV0356 # 17 Y:2007 17 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $488 $40 Implemented
UD0758 # 01 Y:2007 01 2007 REDUCE VENTILATION AIR $24,896 $0 Implemented
UD0758 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,028 $36,900 Not Implemented
UD0758 # 03 Y:2007 03 2007 USE POWER DURING OFF-PEAK PERIODS $12,438 $0 Not Implemented
UD0758 # 04 Y:2007 04 2007 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $10,225 $15,000 Not Implemented
UD0758 # 05 Y:2007 05 2007 USE MINIMUM SAFE OVEN VENTILATION $9,717 $595 Not Implemented
UD0758 # 06 Y:2007 06 2007 RECOVER WASTE HEAT FROM EQUIPMENT $7,786 $0 Not Implemented
UD0758 # 07 Y:2007 07 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $5,657 $0 Implemented
UD0758 # 08 Y:2007 08 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,876 $2,500 Implemented
UD0758 # 09 Y:2007 09 2007 OPTIMIZE PLANT POWER FACTOR $992 $3,000 Not Implemented
UD0758 # 10 Y:2007 10 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $876 $144 Implemented
UD0758 # 11 Y:2007 11 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $538 $0 Not Implemented