IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,345

matching recommendations
Reset
NAICS 333 Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0074 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,504 $360 Implemented
TA0074 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $625 $600 Implemented
AM0465 # 01 Y:2004 01 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $27,500 $1,000 Implemented
AM0465 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $26,300 $1,000 Implemented
AM0465 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,550 $840 Implemented
AM0465 # 04 Y:2004 04 2004 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $7,100 $0 Implemented
AM0465 # 05 Y:2004 05 2004 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $4,500 $300 Not Implemented
AM0465 # 06 Y:2004 06 2004 USE PHOTOCELL CONTROLS $1,605 $570 Implemented
AM0465 # 07 Y:2004 07 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,580 $1,075 Implemented
AM0465 # 08 Y:2004 08 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,370 $900 Implemented
AM0465 # 09 Y:2004 09 2004 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $980 $0 Implemented
AM0465 # 10 Y:2004 10 2004 USE SYNTHETIC LUBRICANT $421 $0 Not Implemented
AM0464 # 01 Y:2004 01 2004 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $28,350 $136,800 Implemented
AM0464 # 02 Y:2004 02 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,500 $500 Implemented
AM0464 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,200 $500 Implemented
AM0464 # 04 Y:2004 04 2004 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,490 $70 Not Implemented
AM0464 # 05 Y:2004 05 2004 USE SYNTHETIC LUBRICANT $1,930 $0 Not Implemented
AM0464 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,840 $770 Implemented
AM0464 # 07 Y:2004 07 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $550 $175 Not Implemented
AM0464 # 08 Y:2004 08 2004 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $26,000 $18,000 Implemented
AM0464 # 09 Y:2004 09 2004 REUSE RAGS UNTIL COMPLETELY SOILED $3,900 $0 Not Implemented
UM0253 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,527 $19,692 Implemented
UM0253 # 02 Y:2004 02 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $9,810 $3,150 Implemented
UM0253 # 03 Y:2004 03 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $5,558 $750 Implemented
UM0253 # 04 Y:2004 04 2004 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,806 $9,583 Implemented