Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
385
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0171 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,050 | $10,345 | Not Implemented |
LE0171 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,863 | $608 | Implemented |
LE0171 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $2,512 | $0 | Not Implemented |
LE0171 # 03 Y:2003 | 03 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,645 | $6,000 | Implemented |
LE0171 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,790 | $0 | Not Implemented |
LE0171 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,638 | $0 | Implemented |
OK0669 # 07 Y:2003 | 07 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,052 | $1,468 | Implemented |
OK0669 # 06 Y:2003 | 06 | 2003 | INSTALL SET-BACK TIMERS | $1,069 | $463 | Implemented |
OK0669 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,966 | $3,467 | Implemented |
OK0669 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,626 | $3,500 | Implemented |
OK0669 # 03 Y:2003 | 03 | 2003 | OPTIMIZE PLANT POWER FACTOR | $19,611 | $12,000 | n/a |
OK0669 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,435 | $8,500 | Implemented |
OK0669 # 01 Y:2003 | 01 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $79,727 | $15,485 | Not Implemented |
NC0262 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,339 | $50 | Not Implemented |
NC0262 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,284 | $800 | Not Implemented |
NC0262 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,272 | $5,225 | Not Implemented |
NC0262 # 03 Y:2003 | 03 | 2003 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $4,320 | $5,653 | Not Implemented |
NC0262 # 02 Y:2003 | 02 | 2003 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $33,773 | $55,000 | Not Implemented |
NC0262 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,471 | $10,000 | Not Implemented |
WI0449 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $905 | $640 | Not Implemented |
WI0449 # 02 Y:2003 | 02 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,417 | $29,500 | Not Implemented |
WI0449 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,045 | $0 | Not Implemented |
WI0449 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $16,308 | $2,000 | Not Implemented |
WI0449 # 05 Y:2003 | 05 | 2003 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $5,783 | $15,000 | Not Implemented |
WI0449 # 06 Y:2003 | 06 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $5,589 | $0 | Not Implemented |