Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,345
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0447 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $631 | $1,080 | Implemented |
SU0447 # 08 Y:2017 | 08 | 2017 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $224 | $903 | Implemented |
MA0782 # 01 Y:2017 | 01 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,221 | $78,750 | Not Implemented |
MA0782 # 02 Y:2017 | 02 | 2017 | INSULATE BARE EQUIPMENT | $7,638 | $1,583 | Implemented |
MA0782 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,366 | $600 | Implemented |
MA0782 # 04 Y:2017 | 04 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $277 | $100 | Implemented |
MA0782 # 05 Y:2017 | 05 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $160 | $100 | Not Implemented |
SU0446 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,759 | $0 | Implemented |
SU0446 # 02 Y:2017 | 02 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,711 | $7,161 | Not Implemented |
SU0446 # 03 Y:2017 | 03 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $304 | $234 | Not Implemented |
SU0446 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $170 | $165 | Implemented |
SU0446 # 05 Y:2017 | 05 | 2017 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $6,295 | $18,204 | Not Implemented |
SU0446 # 06 Y:2017 | 06 | 2017 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $290 | $854 | Not Implemented |
MZ0230 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,978 | $27,450 | Implemented |
MZ0230 # 02 Y:2017 | 02 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,308 | $0 | Implemented |
MZ0230 # 03 Y:2017 | 03 | 2017 | MINIMIZE WATER USAGE | $199 | $30 | Implemented |
MZ0230 # 04 Y:2017 | 04 | 2017 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,896 | $6,500 | Not Implemented |
MZ0230 # 05 Y:2017 | 05 | 2017 | INSULATE BARE EQUIPMENT | $3,927 | $1,050 | Implemented |
MA0775 # 01 Y:2017 | 01 | 2017 | OPTIMIZE PLANT POWER FACTOR | $28,320 | $16,929 | Not Implemented |
MA0775 # 02 Y:2017 | 02 | 2017 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $20,697 | $100 | Implemented |
MA0775 # 03 Y:2017 | 03 | 2017 | AIR CONDITION ONLY SPACE NECESSARY | $13,365 | $7,900 | Not Implemented |
MA0775 # 04 Y:2017 | 04 | 2017 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,486 | $21,000 | Not Implemented |
MA0775 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,966 | $20,488 | Not Implemented |
MA0775 # 06 Y:2017 | 06 | 2017 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $708 | $412 | Not Implemented |
SU0445 # 01 Y:2017 | 01 | 2017 | DISCONNECT BALLASTS | $122 | $0 | Implemented |