Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

6,345

matching recommendations
Reset
NAICS 333 Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0966 # 01 Y:2017 01 2017 REPLACE BOILER $125,000 $442,000 Not Implemented
OK0966 # 02 Y:2017 02 2017 BASE UTILITY CHARGES ON USAGE RATHER THAN AREA OCCUPIED $113,700 $24,000 Implemented
OK0966 # 03 Y:2017 03 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $74,450 $305,694 Implemented
OK0966 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,526 $21,137 Implemented
OK0966 # 05 Y:2017 05 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $7,886 $0 Not Implemented
OK0966 # 06 Y:2017 06 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,570 $17,250 Implemented
OK0966 # 07 Y:2017 07 2017 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,676 $17,550 Implemented
OK0966 # 08 Y:2017 08 2017 COVER OPEN TANKS $2,956 $1,250 Not Implemented
OK0966 # 09 Y:2017 09 2017 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $36 $100 Implemented
NC0593 # 01 Y:2017 01 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,891 $81,460 Implemented
NC0593 # 02 Y:2017 02 2017 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,060 $1,000 Implemented
NC0593 # 03 Y:2017 03 2017 INSTALL OCCUPANCY SENSORS $941 $1,500 Implemented
NC0593 # 04 Y:2017 04 2017 USE PHOTOCELL CONTROLS $223 $100 Implemented
NC0593 # 05 Y:2017 05 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $428 $100 Implemented
NC0593 # 06 Y:2017 06 2017 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $119 $300 Not Implemented
NC0593 # 07 Y:2017 07 2017 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,986 $600 Implemented
WM0103 # 01 Y:2017 01 2017 INSTALL OCCUPANCY SENSORS $2,287 $1,245 Not Implemented
WM0103 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $823 $800 Not Implemented
WM0103 # 03 Y:2017 03 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,337 $24,875 Not Implemented
WM0103 # 04 Y:2017 04 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,488 $302 Not Implemented
WM0103 # 05 Y:2017 05 2017 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,422 $0 Not Implemented
WM0103 # 06 Y:2017 06 2017 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $459 $690 Not Implemented
WM0103 # 07 Y:2017 07 2017 USE SYNTHETIC LUBRICANT $26,785 $47,960 Not Implemented
WM0103 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,484 $3,000 Not Implemented
WM0103 # 09 Y:2017 09 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $131 $0 Not Implemented