IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

547

matching recommendations
Reset
NAICS 3331 Agriculture, Construction, and Mining Machinery Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0381 # 06 Y:2010 06 2010 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $3,502 $6,175 Implemented
SF0381 # 07 Y:2010 07 2010 INSTALL OCCUPANCY SENSORS $841 $2,812 Implemented
AM0554 # 01 Y:2008 01 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $213,800 $45,770 Implemented
AM0554 # 02 Y:2008 02 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $133,000 $1,000 Implemented
AM0554 # 04 Y:2008 04 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $51,670 $2,000 Implemented
AM0554 # 05 Y:2008 05 2008 PAY UTILITY BILLS ON TIME $9,462 $0 Implemented
AM0554 # 06 Y:2008 06 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,900 $5,400 Implemented
AM0554 # 08 Y:2008 08 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,185 $500 Implemented
AM0554 # 09 Y:2008 09 2008 SELL OIL TO RECYCLER $1,240 $0 Implemented
LL0305 # 02 Y:2008 02 2008 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,261 $1,320 Implemented
LL0305 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,846 $3,025 Implemented
LL0305 # 05 Y:2008 05 2008 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,925 $348 Implemented
LL0305 # 06 Y:2008 06 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $853 $490 Implemented
NC0380 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $864 $100 Implemented
NC0380 # 08 Y:2008 08 2008 DEVELOP A REPAIR/REPLACE POLICY $1,283 $1,540 Implemented
WV0379 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $72,979 $113,775 Implemented
WV0379 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $43,378 $60,703 Implemented
WV0379 # 04 Y:2008 04 2008 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $10,617 $13,800 Implemented
WV0379 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $10,262 $1,080 Implemented
WV0379 # 06 Y:2008 06 2008 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $9,977 $700 Implemented
WV0379 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,550 $0 Implemented
WV0379 # 09 Y:2008 09 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,760 $0 Implemented
WV0379 # 10 Y:2008 10 2008 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,723 $1,000 Implemented
WV0379 # 11 Y:2008 11 2008 DEVELOP A REPAIR/REPLACE POLICY $2,610 $763 Implemented
WV0379 # 12 Y:2008 12 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,133 $160 Implemented