Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
740
matching recommendationsNAICS | 3332 | Industrial Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0524 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $3,500 | Implemented |
OR0524 # 03 Y:2007 | 03 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $13,700 | $35,000 | Implemented |
OR0524 # 04 Y:2007 | 04 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,100 | $0 | Implemented |
OR0524 # 05 Y:2007 | 05 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,000 | $0 | Not Implemented |
OR0524 # 06 Y:2007 | 06 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,800 | $1,300 | Not Implemented |
OR0524 # 07 Y:2007 | 07 | 2007 | OPTIMIZE PLANT POWER FACTOR | $13,800 | $19,200 | Not Implemented |
UF0399 # 01 Y:2007 | 01 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,373 | $24,800 | Not Implemented |
UF0399 # 02 Y:2007 | 02 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $349 | $1,376 | Not Implemented |
UF0399 # 03 Y:2007 | 03 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,878 | $437 | Implemented |
UF0399 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,852 | $0 | Implemented |
UF0399 # 05 Y:2007 | 05 | 2007 | USE OPTIMUM THICKNESS INSULATION | $1,157 | $188 | Not Implemented |
UF0399 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $939 | $0 | Not Implemented |
UF0399 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,311 | $44,692 | Not Implemented |
UF0399 # 08 Y:2007 | 08 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $47,277 | $35,000 | Not Implemented |
UF0399 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,017 | $1,719 | Not Implemented |
UF0399 # 10 Y:2007 | 10 | 2007 | INSTALL OCCUPANCY SENSORS | $1,761 | $404 | Implemented |
UF0399 # 11 Y:2007 | 11 | 2007 | RECYCLE FLUORESCENT LAMPS | $1,005 | $3,486 | Implemented |
UF0399 # 12 Y:2007 | 12 | 2007 | CHANGE OPERATING CONDITIONS | $74,852 | $731 | Implemented |
MZ0002 # 01 Y:2007 | 01 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $19,616 | $21,000 | Not Implemented |
MZ0002 # 02 Y:2007 | 02 | 2007 | REPLACE DIRECT FIRED WITH STEAM HEAT | $35,480 | $78,000 | Not Implemented |
MZ0002 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,930 | $40,700 | Implemented |
MZ0002 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $2,300 | $1,475 | Not Implemented |
MZ0002 # 05 Y:2007 | 05 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,700 | $0 | Not Implemented |
MZ0002 # 06 Y:2007 | 06 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,500 | $1,200 | Not Implemented |
IC0126 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,723 | $55,780 | Implemented |