Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
466
matching recommendationsNAICS | 3333 | Commercial and Service Industry Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0382 # 12 Y:2006 | 12 | 2006 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,821 | $0 | Not Implemented |
UF0382 # 13 Y:2006 | 13 | 2006 | RECYCLE FLUORESCENT LAMPS | $342 | $3,237 | Not Implemented |
UF0382 # 14 Y:2006 | 14 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,240 | $8,000 | Not Implemented |
AS0414 # 01 Y:2006 | 01 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $813,934 | $3,030,000 | Not Implemented |
AS0414 # 02 Y:2006 | 02 | 2006 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $28,518 | $20,000 | Implemented |
AS0414 # 03 Y:2006 | 03 | 2006 | PAY BILLS ON TIME TO AVOID LATE FEES | $17,731 | $200 | Implemented |
OR0498 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $7,300 | $3,600 | Implemented |
OR0498 # 02 Y:2006 | 02 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,300 | $0 | Not Implemented |
OR0498 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $2,300 | Implemented |
OR0498 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $1,450 | $1,800 | Not Implemented |
OR0498 # 05 Y:2006 | 05 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $600 | $400 | Implemented |
OR0498 # 06 Y:2006 | 06 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,400 | $20,000 | Implemented |
OR0498 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,600 | $17,400 | Implemented |
AS0399 # 01 Y:2005 | 01 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $200,000 | $19,000 | Not Implemented |
AS0399 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $861 | $1,632 | Not Implemented |
AS0399 # 03 Y:2005 | 03 | 2005 | USE SOLAR HEAT TO HEAT WATER | $690 | $1,100 | Not Implemented |
AS0399 # 04 Y:2005 | 04 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $318 | $506 | Not Implemented |
UM0269 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,237 | $600 | Not Implemented |
UM0269 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,834 | $1,275 | Not Implemented |
UM0269 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,913 | $2,890 | Not Implemented |
UM0269 # 04 Y:2004 | 04 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,128 | $3,000 | Not Implemented |
UM0269 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,435 | $2,000 | Not Implemented |
UM0269 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,285 | $400 | Not Implemented |
UM0269 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $220 | $276 | Not Implemented |
SU0196 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,000 | $0 | Implemented |