Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
958
matching recommendationsNAICS | 33341 | Ventilation, Heating, Air-Conditioning, and Commercial Refrigeration Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0452 # 04 Y:2012 | 04 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,198 | $8,840 | Not Implemented |
WV0452 # 03 Y:2012 | 03 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $21,578 | $4,825 | Implemented |
WV0452 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,485 | $98,452 | Not Implemented |
WV0452 # 01 Y:2012 | 01 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $50,506 | $36,000 | Not Implemented |
WV0452 # 16 Y:2012 | 16 | 2012 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $277 | $85 | Implemented |
WV0452 # 10 Y:2012 | 10 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,515 | $2,117 | Not Implemented |
WV0452 # 14 Y:2012 | 14 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $873 | $4,350 | Not Implemented |
WV0452 # 15 Y:2012 | 15 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $431 | $1,505 | Not Implemented |
WV0452 # 13 Y:2012 | 13 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,098 | $1,105 | Implemented |
WV0452 # 12 Y:2012 | 12 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,146 | $618 | Implemented |
MZ0088 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $532 | $800 | Not Implemented |
MZ0088 # 02 Y:2012 | 02 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,179 | $11,250 | Not Implemented |
MZ0088 # 03 Y:2012 | 03 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,833 | $0 | Not Implemented |
MZ0088 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,252 | $2,400 | Not Implemented |
MZ0088 # 05 Y:2012 | 05 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $698 | $1,200 | Not Implemented |
GT0892 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,198 | $0 | Implemented |
GT0892 # 02 Y:2012 | 02 | 2012 | IMPROVE LUBRICATION PRACTICES | $8,776 | $0 | Not Implemented |
GT0892 # 03 Y:2012 | 03 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,344 | $111,720 | Not Implemented |
GT0892 # 04 Y:2012 | 04 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,679 | $29,200 | Not Implemented |
GT0892 # 05 Y:2012 | 05 | 2012 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,630 | $1,000 | Implemented |
GT0892 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,558 | $21,000 | Not Implemented |
GT0892 # 07 Y:2012 | 07 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $16,320 | $82,800 | Not Implemented |
MZ0077 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,655 | $800 | Not Implemented |
MZ0077 # 06 Y:2011 | 06 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $38,690 | $0 | Not Implemented |
MZ0077 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,741 | $28,000 | Not Implemented |