Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
800
matching recommendationsNAICS | 3335 | Metalworking Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0409 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,490 | $600 | Implemented |
WV0409 # 08 Y:2010 | 08 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,480 | $0 | Implemented |
WV0409 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,292 | $3,520 | Implemented |
WV0409 # 10 Y:2010 | 10 | 2010 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,165 | $400 | Not Implemented |
WV0409 # 11 Y:2010 | 11 | 2010 | USE OPTIMUM THICKNESS INSULATION | $1,139 | $625 | Not Implemented |
WV0409 # 12 Y:2010 | 12 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $544 | $690 | Not Implemented |
UM0364 # 01 Y:2010 | 01 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,260 | $8,716 | Not Implemented |
UM0364 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,618 | $7,917 | Implemented |
UM0364 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $1,498 | $1,464 | Not Implemented |
UM0364 # 04 Y:2010 | 04 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $913 | $2,000 | Implemented |
UM0364 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,885 | $5,500 | Implemented |
UM0364 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,735 | $500 | Implemented |
UM0362 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,064 | $1,500 | Not Implemented |
UM0362 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,058 | $89,000 | Implemented |
UM0362 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,351 | $500 | Implemented |
UM0362 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,185 | $400 | Implemented |
UM0362 # 05 Y:2010 | 05 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,961 | $3,048 | Implemented |
UM0362 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $3,523 | $6,072 | Not Implemented |
UM0362 # 07 Y:2010 | 07 | 2010 | INSTALL STORM WINDOWS AND DOORS | $3,301 | $3,000 | Implemented |
UM0362 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,257 | $2,000 | Implemented |
SU0287 # 01 Y:2010 | 01 | 2010 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,962 | $0 | Implemented |
SU0287 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,424 | $0 | Implemented |
SU0287 # 03 Y:2010 | 03 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,705 | $0 | Implemented |
SU0287 # 04 Y:2010 | 04 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,358 | $0 | Not Implemented |
SU0287 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,950 | $338 | Implemented |