Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsNAICS | 3335 | Metalworking Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0626 # 02 Y:2007 | 02 | 2007 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $6,543 | $8,000 | Not Implemented |
MA0626 # 03 Y:2007 | 03 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $5,346 | $0 | Not Implemented |
MA0626 # 04 Y:2007 | 04 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $3,465 | $2,500 | Not Implemented |
MA0626 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,602 | $5,481 | Not Implemented |
MA0626 # 06 Y:2007 | 06 | 2007 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $395 | $200 | Not Implemented |
MA0626 # 01 Y:2007 | 01 | 2007 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $67,278 | $157,500 | Not Implemented |
UM0331 # 05 Y:2007 | 05 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $606 | $0 | Implemented |
UM0331 # 04 Y:2007 | 04 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $788 | $500 | Not Implemented |
UM0331 # 03 Y:2007 | 03 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $2,277 | $4,600 | Not Implemented |
UM0331 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,146 | $12,000 | Implemented |
UM0331 # 01 Y:2007 | 01 | 2007 | RECOVER AND REUSE WASTE MATERIAL | $37,752 | $38,000 | Not Implemented |
SU0259 # 01 Y:2007 | 01 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,279 | $0 | Implemented |
SU0259 # 02 Y:2007 | 02 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,332 | $0 | Not Implemented |
SU0259 # 03 Y:2007 | 03 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $411 | $0 | Not Implemented |
SU0259 # 04 Y:2007 | 04 | 2007 | AIR CONDITION ONLY SPACE NECESSARY | $763 | $13 | Implemented |
SU0259 # 07 Y:2007 | 07 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $410 | $232 | Implemented |
SU0259 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $272 | $231 | Implemented |
SU0259 # 05 Y:2007 | 05 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $290 | $38 | Implemented |
SU0259 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $508 | $546 | Not Implemented |
SU0259 # 10 Y:2007 | 10 | 2007 | INSTALL OCCUPANCY SENSORS | $302 | $973 | Implemented |
SU0259 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $221 | $50 | Implemented |
WV0357 # 08 Y:2007 | 08 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,455 | $2,800 | Not Implemented |
WV0357 # 13 Y:2007 | 13 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $546 | $25 | Implemented |
WV0357 # 07 Y:2007 | 07 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,629 | $1,601 | Implemented |
WV0357 # 06 Y:2007 | 06 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,725 | $625 | Not Implemented |