Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
800
matching recommendationsNAICS | 33351 | Metalworking Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0694 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,630 | $470 | Not Implemented |
CO0694 # 02 Y:2014 | 02 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $7,790 | $1,500 | Not Implemented |
CO0694 # 03 Y:2014 | 03 | 2014 | USE PHOTOCELL CONTROLS | $3,870 | $7,930 | Not Implemented |
CO0694 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,480 | $9,250 | Not Implemented |
SD0485 # 01 Y:2014 | 01 | 2014 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $117,088 | $25,225 | Not Implemented |
SD0485 # 02 Y:2014 | 02 | 2014 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $31,720 | $5,000 | Implemented |
SD0485 # 03 Y:2014 | 03 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $25,053 | $91,900 | Implemented |
SD0485 # 04 Y:2014 | 04 | 2014 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $13,807 | $28,125 | Implemented |
SD0485 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,114 | $1,000 | Implemented |
SD0485 # 06 Y:2014 | 06 | 2014 | USE PHOTOCELL CONTROLS | $1,975 | $5,550 | Implemented |
SD0485 # 07 Y:2014 | 07 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,832 | $4,400 | Implemented |
MZ0142 # 01 Y:2014 | 01 | 2014 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $5,862 | $6,500 | Not Implemented |
MZ0142 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $505 | $1,000 | Not Implemented |
MZ0142 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,716 | $2,500 | Not Implemented |
MZ0142 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $206 | $720 | Not Implemented |
MZ0142 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,435 | $31,000 | Implemented |
MZ0142 # 06 Y:2014 | 06 | 2014 | USE PHOTOCELL CONTROLS | $1,432 | $980 | Not Implemented |
MA0728 # 01 Y:2014 | 01 | 2014 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $16,512 | $25,775 | Implemented |
MA0728 # 02 Y:2014 | 02 | 2014 | REPLACE BOILER | $10,114 | $30,450 | Implemented |
MA0728 # 03 Y:2014 | 03 | 2014 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,940 | $6,500 | Implemented |
MA0728 # 04 Y:2014 | 04 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $324 | $350 | Not Implemented |
BD0439 # 01 Y:2013 | 01 | 2013 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $6,296 | $50 | Implemented |
BD0439 # 02 Y:2013 | 02 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $4,775 | $6,000 | Not Implemented |
BD0439 # 03 Y:2013 | 03 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,900 | $1,000 | Implemented |
BD0439 # 04 Y:2013 | 04 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,797 | $3,310 | Not Implemented |