Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
548
matching recommendationsNAICS | 33361 | Engine, Turbine, and Power Transmission Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0067 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,567 | $29,205 | Not Implemented |
IC0067 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,441 | $72,201 | n/a |
IC0067 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,742 | $4,527 | Not Implemented |
IC0067 # 06 Y:2003 | 06 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,376 | $0 | Implemented |
IC0067 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,728 | $19,284 | Not Implemented |
IC0067 # 08 Y:2003 | 08 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,670 | $0 | Not Implemented |
IC0067 # 09 Y:2003 | 09 | 2003 | REDUCE OR ELIMINATE WASTE | $13,650 | $2,107 | Not Implemented |
LL0174 # 01 Y:2003 | 01 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $17,499 | $7,098 | Not Implemented |
LL0174 # 02 Y:2003 | 02 | 2003 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,785 | $880 | Implemented |
LL0174 # 03 Y:2003 | 03 | 2003 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,515 | $763 | Not Implemented |
LL0174 # 04 Y:2003 | 04 | 2003 | USE PHOTOCELL CONTROLS | $582 | $28 | Implemented |
LL0174 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $443 | $360 | Not Implemented |
LL0174 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $384 | $56 | Implemented |
LL0174 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $386 | $280 | Implemented |
LL0174 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $430 | $32 | Not Implemented |
NC0263 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $118,487 | $500 | Not Implemented |
NC0263 # 02 Y:2003 | 02 | 2003 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $22,423 | $10,000 | Not Implemented |
NC0263 # 03 Y:2003 | 03 | 2003 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $33,114 | $24,600 | Not Implemented |
NC0263 # 04 Y:2003 | 04 | 2003 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $47,210 | $100,000 | Implemented |
NC0263 # 05 Y:2003 | 05 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $8,768 | $10,000 | Not Implemented |
NC0263 # 06 Y:2003 | 06 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $46,271 | $135,400 | Not Implemented |
NC0263 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $556 | $680 | Implemented |
NC0263 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $413 | $240 | Implemented |