Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,619
matching recommendationsNAICS | 3339 | Other General Purpose Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0352 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,182 | $1 | Not Implemented |
IA0352 # 05 Y:2004 | 05 | 2004 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $12,016 | $2 | Implemented |
IA0352 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $528 | $136 | Implemented |
IA0352 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,595 | $6,618 | Implemented |
IA0352 # 08 Y:2004 | 08 | 2004 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $4,044 | $440 | Not Implemented |
IA0352 # 09 Y:2004 | 09 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $867,815 | $171 | Implemented |
IA0350 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $703 | $290 | Implemented |
IA0350 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $197 | $25 | Implemented |
IA0350 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $985 | Implemented |
IA0350 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $967 | $4,398 | Implemented |
IA0350 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $207 | $732 | Implemented |
IA0350 # 06 Y:2004 | 06 | 2004 | USE RADIANT HEATER FOR SPOT HEATING | $11,055 | $14,814 | Not Implemented |
IA0350 # 07 Y:2004 | 07 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $626 | $1,600 | Not Implemented |
IA0348 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $9,818 | $10,704 | Implemented |
IA0348 # 02 Y:2004 | 02 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,336 | $475 | Not Implemented |
IA0348 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $651 | $146 | Implemented |
IA0348 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,888 | $535 | Implemented |
IA0348 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,829 | $14,216 | Implemented |
IA0348 # 06 Y:2004 | 06 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $193 | $438 | Not Implemented |
IA0348 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $383 | $120 | Not Implemented |
IA0348 # 08 Y:2004 | 08 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,653 | $4,596 | Implemented |
OR0470 # 01 Y:2004 | 01 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $92,000 | $1,200 | Not Implemented |
OR0470 # 02 Y:2004 | 02 | 2004 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $11,400 | $2,800 | Not Implemented |
OR0470 # 03 Y:2004 | 03 | 2004 | ELIMINATE/REDUCE AN OPERATION | $9,627 | $250 | Not Implemented |
OR0470 # 04 Y:2004 | 04 | 2004 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,990 | $300 | Not Implemented |