Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
299
matching recommendationsNAICS | 333911 | Pump and Pumping Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0659 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,940 | $11,920 | Not Implemented |
LE0355 # 07 Y:2013 | 07 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,174 | $1,200 | Implemented |
LE0355 # 06 Y:2013 | 06 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,029 | $9,000 | Not Implemented |
LE0355 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,537 | $5,280 | Not Implemented |
LE0355 # 04 Y:2013 | 04 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,970 | $2,640 | Implemented |
LE0355 # 03 Y:2013 | 03 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $803 | $1,900 | Not Implemented |
LE0355 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,383 | $11,830 | Not Implemented |
LE0355 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $6,254 | $26,400 | Not Implemented |
LE0355 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,879 | $1,000 | Implemented |
LE0355 # 08 Y:2013 | 08 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $13,937 | $25,932 | Not Implemented |
OK0859 # 01 Y:2013 | 01 | 2013 | USE EXISTING DAM TO GENERATE ELECTRICITY | $12,404 | $65,000 | Not Implemented |
OK0859 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,187 | $7,856 | Implemented |
OK0859 # 03 Y:2013 | 03 | 2013 | DISCONNECT BALLASTS | $342 | $900 | Not Implemented |
OK0859 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $975 | Not Implemented |
OK0859 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $327 | $2,550 | Not Implemented |
OK0859 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,550 | $3,000 | Implemented |
OK0859 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,135 | $3,356 | Not Implemented |
OK0859 # 08 Y:2013 | 08 | 2013 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $20,774 | $7,707 | Not Implemented |
OK0859 # 09 Y:2013 | 09 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,338 | $4,600 | Not Implemented |
OK0859 # 10 Y:2013 | 10 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $17,170 | $30,000 | Implemented |
OK0859 # 11 Y:2013 | 11 | 2013 | INSTALL SET-BACK TIMERS | $1,753 | $460 | Not Implemented |
OK0859 # 12 Y:2013 | 12 | 2013 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,487 | $3,063 | Not Implemented |
OK0859 # 13 Y:2013 | 13 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $3,200 | $6,500 | Implemented |
OK0859 # 14 Y:2013 | 14 | 2013 | REDUCE HEAT GAIN BY WINDOW TINTING | $372 | $0 | Implemented |
AM0642 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $6,760 | $22,800 | Not Implemented |