Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

30

matching recommendations
Reset
NAICS 333992 Welding and Soldering Equipment Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0199 # 08 Y:2010 08 2010 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $4,552 $4,531 Implemented
MI0199 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,329 $1,210 Implemented
MI0199 # 02 Y:2010 02 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $31,106 $2,000 Implemented
MI0199 # 01 Y:2010 01 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $37,073 $6,280 Implemented
MI0199 # 04 Y:2010 04 2010 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $10,308 $7,450 Implemented
MI0199 # 05 Y:2010 05 2010 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,954 $2,200 Implemented
MI0199 # 06 Y:2010 06 2010 INSULATE BARE EQUIPMENT $8,626 $1,786 Not Implemented
MI0199 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,254 $5,975 Implemented
GT0845 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,571 $31,022 Not Implemented
GT0845 # 02 Y:2007 02 2007 COMBINE UTILITY METERS $6,697 $0 Not Implemented
GT0845 # 03 Y:2007 03 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,196 $0 Not Implemented
GT0845 # 04 Y:2007 04 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,129 $26,550 Not Implemented
GT0845 # 05 Y:2007 05 2007 INSTALL TIMERS AND/OR THERMOSTATS $8,290 $4,750 Implemented
GT0845 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,215 $2,000 Implemented
GT0845 # 07 Y:2007 07 2007 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $3,956 $4,000 Not Implemented
GT0845 # 08 Y:2007 08 2007 INSTALL OCCUPANCY SENSORS $3,215 $3,600 Not Implemented
CO0584 # 02 Y:2006 02 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,220 $31,750 Implemented
CO0584 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $820 $740 Not Implemented
CO0584 # 05 Y:2006 05 2006 USE SOLAR HEAT TO MAKE ELECTRICTY $1,500 $2,950 Not Implemented
CO0584 # 04 Y:2006 04 2006 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,130 $16,160 Not Implemented
CO0584 # 03 Y:2006 03 2006 USE SOLAR HEAT TO HEAT MAKE-UP AIR $3,480 $21,810 Not Implemented
CO0584 # 01 Y:2006 01 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $210 $0 Not Implemented
UM0262 # 01 Y:2004 01 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $3,974 $1,200 Not Implemented
UM0262 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,373 $300 Not Implemented
UM0262 # 03 Y:2004 03 2004 AIR CONDITION ONLY SPACE NECESSARY $2,293 $1,410 Not Implemented