Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

76

matching recommendations
Reset
NAICS 334516 Analytical Laboratory Instrument Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0573 # 04 Y:2016 04 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $105 $200 Implemented
SU0414 # 06 Y:2016 06 2016 REDUCE VENTILATION AIR $1,286 $1,309 Implemented
SU0414 # 02 Y:2016 02 2016 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $699 $0 Implemented
SU0414 # 01 Y:2016 01 2016 ELIMINATE/REDUCE AN OPERATION $793 $0 Implemented
SU0414 # 04 Y:2016 04 2016 ELIMINATE/REDUCE AN OPERATION $124 $0 Implemented
SU0414 # 03 Y:2016 03 2016 PAY UTILITY BILLS ON TIME $283 $0 Implemented
SU0414 # 11 Y:2016 11 2016 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $153 $359 Implemented
SU0414 # 07 Y:2016 07 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $493 $691 Implemented
DL0162 # 06 Y:2016 06 2016 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $18,175 $10,500 Implemented
DL0162 # 01 Y:2016 01 2016 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $22,170 $0 Implemented
DL0162 # 02 Y:2016 02 2016 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $7,660 $0 Implemented
DL0162 # 04 Y:2016 04 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $3,605 $800 Implemented
DL0162 # 07 Y:2016 07 2016 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,730 $1,820 Implemented
DL0162 # 08 Y:2016 08 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,930 $29,230 Implemented
DL0160 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,935 $211,395 Implemented
DL0160 # 02 Y:2016 02 2016 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,550 $0 Implemented
OR0650 # 05 Y:2015 05 2015 HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE $1,291 $4,404 Implemented
OR0650 # 03 Y:2015 03 2015 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS $719 $1,200 Implemented
MI0254 # 14 Y:2014 14 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $447 $80 Implemented
MI0254 # 10 Y:2014 10 2014 INSTALL OCCUPANCY SENSORS $3,162 $800 Implemented
MI0254 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,949 $13,170 Implemented
MI0254 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,680 $2,160 Implemented
MI0254 # 06 Y:2014 06 2014 OPTIMIZE PLANT POWER FACTOR $5,083 $7,680 Implemented
MI0254 # 03 Y:2014 03 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $17,716 $3,100 Implemented
MI0254 # 02 Y:2014 02 2014 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $45,927 $80 Implemented