IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,095

matching recommendations
Reset
NAICS 335 Electrical Equipment, Appliance, and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0286 # 08 Y:2009 08 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $400 $457 Not Implemented
SU0286 # 09 Y:2009 09 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $318 $337 Not Implemented
SU0286 # 10 Y:2009 10 2009 INSTALL OCCUPANCY SENSORS $102 $664 Not Implemented
SD0415 # 01 Y:2009 01 2009 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $6,503 $18,750 Implemented
SD0415 # 02 Y:2009 02 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,780 $7,974 Not Implemented
SD0415 # 03 Y:2009 03 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,009 $0 Implemented
SD0415 # 04 Y:2009 04 2009 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,047 $0 Not Implemented
SD0415 # 05 Y:2009 05 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,035 $128 Implemented
SD0415 # 06 Y:2009 06 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $910 $1,000 Implemented
SD0415 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $657 $5,864 Not Implemented
SD0415 # 08 Y:2009 08 2009 INSTALL SKYLIGHTS $323 $1,470 Not Implemented
SD0415 # 09 Y:2009 09 2009 INSTALL OCCUPANCY SENSORS $154 $347 Implemented
SF0370 # 01 Y:2009 01 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $316 $0 Not Implemented
SF0370 # 02 Y:2009 02 2009 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,936 $2,464 Not Implemented
SF0370 # 03 Y:2009 03 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $684 $849 Not Implemented
SF0370 # 04 Y:2009 04 2009 INSULATE BARE EQUIPMENT $942 $2,473 Not Implemented
SF0370 # 05 Y:2009 05 2009 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $972 $2,956 Not Implemented
SF0370 # 06 Y:2009 06 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $1,614 $7,537 Not Implemented
SF0370 # 07 Y:2009 07 2009 INSTALL OCCUPANCY SENSORS $1,231 $10,326 Not Implemented
SF0370 # 08 Y:2009 08 2009 USE SOLAR HEAT TO MAKE ELECTRICTY $74,612 $654,810 Not Implemented
TT0034 # 01 Y:2009 01 2009 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $20,000 $47,500 Not Implemented
TT0034 # 02 Y:2009 02 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,800 $2,500 Not Implemented
TT0034 # 03 Y:2009 03 2009 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $3,250 $4,800 Not Implemented
TT0034 # 04 Y:2009 04 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,900 $800 Implemented
TT0034 # 05 Y:2009 05 2009 UTILIZE A LESS EXPENSIVE COOLING METHOD $13,300 $20,000 Not Implemented