Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
736
matching recommendationsNAICS | 33531 | Electrical Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0571 # 01 Y:2010 | 01 | 2010 | OPTIMIZE PLANT POWER FACTOR | $34,630 | $98,400 | Not Implemented |
AM0571 # 02 Y:2010 | 02 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $33,740 | $2,160 | Not Implemented |
AM0571 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,200 | $300 | Implemented |
AM0571 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,010 | $31,300 | Implemented |
AM0571 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,400 | $1,500 | Implemented |
AM0571 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,700 | $1,900 | Implemented |
AM0571 # 07 Y:2010 | 07 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,605 | $0 | Implemented |
AM0571 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,000 | $1,500 | Implemented |
SU0286 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,756 | $0 | Implemented |
SU0286 # 02 Y:2009 | 02 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,876 | $0 | Not Implemented |
SU0286 # 03 Y:2009 | 03 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $4,389 | $0 | Not Implemented |
SU0286 # 04 Y:2009 | 04 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,215 | $0 | Implemented |
SU0286 # 05 Y:2009 | 05 | 2009 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,974 | $0 | Not Implemented |
SU0286 # 06 Y:2009 | 06 | 2009 | DISCONNECT BALLASTS | $1,462 | $0 | Not Implemented |
SU0286 # 07 Y:2009 | 07 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,080 | $287 | Implemented |
SU0286 # 08 Y:2009 | 08 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $400 | $457 | Not Implemented |
SU0286 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $318 | $337 | Not Implemented |
SU0286 # 10 Y:2009 | 10 | 2009 | INSTALL OCCUPANCY SENSORS | $102 | $664 | Not Implemented |
SD0415 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,503 | $18,750 | Implemented |
SD0415 # 02 Y:2009 | 02 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,780 | $7,974 | Not Implemented |
SD0415 # 03 Y:2009 | 03 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,009 | $0 | Implemented |
SD0415 # 04 Y:2009 | 04 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,047 | $0 | Not Implemented |
SD0415 # 05 Y:2009 | 05 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,035 | $128 | Implemented |
SD0415 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $910 | $1,000 | Implemented |
SD0415 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $657 | $5,864 | Not Implemented |