Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,027
matching recommendationsNAICS | 3359 | Other Electrical Equipment and Component Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0430 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $30,360 | $161,900 | Not Implemented |
MA0668 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,378 | $1,800 | Implemented |
MA0668 # 02 Y:2011 | 02 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $7,899 | $11,500 | Implemented |
MA0668 # 03 Y:2011 | 03 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,401 | $11,610 | Implemented |
MA0668 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $3,004 | $3,750 | Implemented |
MA0668 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,755 | $200 | Not Implemented |
MA0668 # 06 Y:2011 | 06 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,802 | $7,000 | Not Implemented |
MA0668 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $986 | $950 | Implemented |
SU0306 # 01 Y:2011 | 01 | 2011 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $19,413 | $0 | Implemented |
SU0306 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,375 | $0 | Implemented |
SU0306 # 03 Y:2011 | 03 | 2011 | RECOVER AND REUSE SPENT ACID BATHS | $49,465 | $4,029 | Implemented |
SU0306 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,901 | $337 | Implemented |
SU0306 # 05 Y:2011 | 05 | 2011 | RECOVER AND REUSE COOLING WATER | $32,137 | $12,052 | Implemented |
SU0306 # 06 Y:2011 | 06 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,700 | $35,000 | Not Implemented |
SU0306 # 07 Y:2011 | 07 | 2011 | OPTIMIZE PLANT POWER FACTOR | $8,914 | $55,516 | Not Implemented |
GT0879 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,235 | $1 | Not Implemented |
GT0879 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,458 | $56,350 | Not Implemented |
GT0879 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $3,260 | $4,050 | Not Implemented |
GT0879 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,254 | $2,500 | Implemented |
GT0879 # 05 Y:2011 | 05 | 2011 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $4,339 | $8,740 | Not Implemented |
GT0879 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $339,042 | $1,340,000 | Not Implemented |
IA0458 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,473 | $1,020 | Implemented |
IA0458 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,769 | $2,181 | Implemented |
IA0458 # 03 Y:2010 | 03 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $48,853 | $11,000 | Implemented |
IA0458 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,520 | $2,139 | Not Implemented |