IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,027

matching recommendations
Reset
NAICS 3359 Other Electrical Equipment and Component Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0232 # 13 Y:2006 13 2006 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $517 $1,545 Not Implemented
SU0232 # 14 Y:2006 14 2006 INSTALL OCCUPANCY SENSORS $651 $2,039 Not Implemented
SU0232 # 15 Y:2006 15 2006 OPTIMIZE PLANT POWER FACTOR $1,024 $9,635 Not Implemented
LM0109 # 02 Y:2006 02 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $408 $586 Implemented
LM0109 # 03 Y:2006 03 2006 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $13,210 $90,000 Implemented
LM0109 # 04 Y:2006 04 2006 AUTOMATE FINISHING PROCESS $240,621 $225,000 Not Implemented
LM0109 # 05 Y:2006 05 2006 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $220,603 $170,000 Not Implemented
LM0109 # 06 Y:2006 06 2006 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $14,573 $120,000 Implemented
LM0109 # 07 Y:2006 07 2006 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $8,917 $7,000 Implemented
LM0109 # 01 Y:2006 01 2006 USE POWER DURING OFF-PEAK PERIODS $65,901 $200,000 Implemented
LM0110 # 01 Y:2006 01 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,799 $90,000 Implemented
LM0110 # 02 Y:2006 02 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,085 $5,844 Not Implemented
LM0110 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $116,775 $100,000 Not Implemented
LM0110 # 04 Y:2006 04 2006 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $85,569 $90,000 Not Implemented
LM0110 # 05 Y:2006 05 2006 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $193,195 $15,800 Not Implemented
LM0110 # 06 Y:2006 06 2006 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $153,608 $23,700 Implemented
WV0330 # 01 Y:2005 01 2005 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $14,602 $0 Implemented
WV0330 # 02 Y:2005 02 2005 ADD AREA LIGHTING SWITCHES $3,316 $1,325 Implemented
WV0330 # 03 Y:2005 03 2005 INSTALL SPECTRAL REFLECTORS / DELAMP $1,364 $3,679 Not Implemented
WV0330 # 04 Y:2005 04 2005 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,049 $35 Implemented
WV0330 # 05 Y:2005 05 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $789 $6 Implemented
WV0330 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $508 $105 Implemented
WV0330 # 07 Y:2005 07 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $474 $140 Not Implemented
WV0330 # 08 Y:2005 08 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $138 $95 Implemented
CO0571 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,580 $500 Implemented