Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
301
matching recommendationsNAICS | 33593 | Wiring Device Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0330 # 01 Y:2005 | 01 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,602 | $0 | Implemented |
WV0330 # 02 Y:2005 | 02 | 2005 | ADD AREA LIGHTING SWITCHES | $3,316 | $1,325 | Implemented |
WV0330 # 03 Y:2005 | 03 | 2005 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,364 | $3,679 | Not Implemented |
WV0330 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,049 | $35 | Implemented |
WV0330 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $789 | $6 | Implemented |
WV0330 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $508 | $105 | Implemented |
WV0330 # 07 Y:2005 | 07 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $474 | $140 | Not Implemented |
WV0330 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $138 | $95 | Implemented |
MI0116 # 01 Y:2005 | 01 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,754 | $2,512 | Implemented |
MI0116 # 02 Y:2005 | 02 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $39,673 | $4,275 | Not Implemented |
MI0116 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,648 | $1,074 | Implemented |
MI0116 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,032 | $56 | Not Implemented |
MI0116 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,307 | $47 | Not Implemented |
MI0116 # 06 Y:2005 | 06 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,244 | $759 | Not Implemented |
MI0116 # 07 Y:2005 | 07 | 2005 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,267 | $0 | Implemented |
AM0485 # 01 Y:2005 | 01 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $25,045 | $660 | Implemented |
AM0485 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,290 | $600 | Implemented |
AM0485 # 03 Y:2005 | 03 | 2005 | OPTIMIZE PLANT POWER FACTOR | $4,150 | $11,235 | Not Implemented |
AM0485 # 04 Y:2005 | 04 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,130 | $0 | Implemented |
AM0485 # 05 Y:2005 | 05 | 2005 | USE SYNTHETIC LUBRICANT | $715 | $0 | Not Implemented |
AM0485 # 06 Y:2005 | 06 | 2005 | PAY UTILITY BILLS ON TIME | $270 | $0 | Implemented |
AM0485 # 07 Y:2005 | 07 | 2005 | COMBINE UTILITY METERS | $212 | $0 | Implemented |
AM0485 # 08 Y:2005 | 08 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $800 | $320 | Not Implemented |
AM0485 # 09 Y:2005 | 09 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $425 | $170 | Not Implemented |
MI0094 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,368 | $2,300 | Implemented |