Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,773
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0084 # 02 Y:2012 | 02 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,919 | $640 | Not Implemented |
UA0084 # 03 Y:2012 | 03 | 2012 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $5,106 | $2,157 | Implemented |
UA0084 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,492 | $9,195 | Implemented |
UA0084 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,491 | $800 | Not Implemented |
UA0084 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,837 | $4,093 | Not Implemented |
UA0084 # 07 Y:2012 | 07 | 2012 | PAY UTILITY BILLS ON TIME | $812 | $30 | Implemented |
LL0369 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $54,656 | $11,200 | Not Implemented |
LL0369 # 02 Y:2012 | 02 | 2012 | USE PHOTOCELL CONTROLS | $3,740 | $120 | Not Implemented |
LL0369 # 03 Y:2012 | 03 | 2012 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,943 | $630 | Not Implemented |
LL0369 # 04 Y:2012 | 04 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,500 | $660 | Not Implemented |
LL0369 # 05 Y:2012 | 05 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $584 | $735 | Not Implemented |
LL0369 # 06 Y:2012 | 06 | 2012 | INSTALL OCCUPANCY SENSORS | $419 | $735 | Not Implemented |
LL0369 # 07 Y:2012 | 07 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $200 | $155 | Not Implemented |
LL0369 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $188 | $213 | Not Implemented |
LL0369 # 09 Y:2012 | 09 | 2012 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $10,920 | $2,084 | Not Implemented |
WM0008 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,760 | $0 | Not Implemented |
WM0008 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,834 | $0 | Not Implemented |
WM0008 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,802 | $0 | Not Implemented |
WM0008 # 04 Y:2012 | 04 | 2012 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $40,676 | $83,400 | Not Implemented |
WM0008 # 05 Y:2012 | 05 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,551 | $1,000 | Not Implemented |
WM0008 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,737 | $0 | Not Implemented |
WM0008 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $432 | $520 | Not Implemented |
WM0008 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $1,209 | $990 | Not Implemented |
WM0008 # 09 Y:2012 | 09 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,137 | $3,034 | Not Implemented |
WM0008 # 10 Y:2012 | 10 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $840 | $400 | Not Implemented |