Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsNAICS | 336 | Transportation Equipment Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0002 # 06 Y:2012 | 06 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $11,459 | $0 | Not Implemented |
WM0002 # 07 Y:2012 | 07 | 2012 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,884 | $0 | Implemented |
IC0189 # 01 Y:2011 | 01 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,166 | $0 | Implemented |
IC0189 # 02 Y:2011 | 02 | 2011 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $156,506 | $686,583 | Implemented |
IC0189 # 03 Y:2011 | 03 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $12,266 | $100,000 | Implemented |
IC0189 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,263 | $1,142 | Implemented |
IC0189 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,441 | $382 | Implemented |
IC0189 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43 | $58 | Implemented |
IC0189 # 07 Y:2011 | 07 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $294 | $0 | Not Implemented |
IC0136 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,802 | $9,080 | Implemented |
IC0136 # 02 Y:2007 | 02 | 2007 | INSTALL OCCUPANCY SENSORS | $2,224 | $5,038 | Implemented |
IC0136 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,294 | $5,851 | Not Implemented |
IC0136 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,389 | $3,105 | Implemented |
IC0136 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,287 | $17,000 | Not Implemented |
IC0136 # 06 Y:2007 | 06 | 2007 | REDUCE VENTILATION AIR | $23,044 | $0 | Not Implemented |
IC0136 # 07 Y:2007 | 07 | 2007 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $9,042 | $26,000 | Not Implemented |
IC0129 # 01 Y:2007 | 01 | 2007 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,537 | $81,554 | Implemented |
IC0129 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,611 | $1,035 | Implemented |
IC0129 # 03 Y:2007 | 03 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,183 | $4,040 | Not Implemented |
IC0129 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,613 | $22,008 | Implemented |
IC0129 # 05 Y:2007 | 05 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $561 | $0 | Implemented |
IC0129 # 06 Y:2007 | 06 | 2007 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,946 | $2,902 | Implemented |
IC0129 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $506 | $1,782 | Implemented |
IC0129 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,264 | $0 | Implemented |
WI0522 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $69,304 | $182,880 | Implemented |