Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
182
matching recommendationsNAICS | 336211 | Motor Vehicle Body Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0550 # 02 Y:2016 | 02 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,410 | $8,190 | Implemented |
IA0550 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,340 | $397 | Implemented |
IA0550 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $671 | $3,170 | Implemented |
IA0550 # 06 Y:2016 | 06 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,127 | $4,280 | Implemented |
IA0550 # 07 Y:2016 | 07 | 2016 | INSTALL OCCUPANCY SENSORS | $540 | $1,300 | Implemented |
NC0550 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $634 | $100 | Implemented |
NC0550 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,015 | $984 | Implemented |
NC0550 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,742 | $46,719 | Implemented |
IA0533 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,857 | $19,775 | Implemented |
IA0533 # 02 Y:2015 | 02 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,005 | $1,049 | Implemented |
IA0533 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,225 | $7,848 | Implemented |
IA0533 # 04 Y:2015 | 04 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,136 | $210 | Implemented |
IA0533 # 06 Y:2015 | 06 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,994 | $4,066 | Implemented |
IA0533 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $993 | $1,342 | Implemented |
WV0499 # 04 Y:2015 | 04 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,878 | $1,000 | Implemented |
WV0499 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,695 | $3,343 | Implemented |
WV0499 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,825 | $20 | Implemented |
WV0499 # 09 Y:2015 | 09 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $792 | $0 | Implemented |
WV0499 # 10 Y:2015 | 10 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $781 | $569 | Implemented |
TT0126 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $5,874 | $24,000 | Implemented |
TT0126 # 02 Y:2014 | 02 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,406 | $7,500 | Implemented |
TT0126 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,851 | $4,000 | Implemented |
TT0126 # 04 Y:2014 | 04 | 2014 | DISCONNECT BALLASTS | $346 | $110 | Implemented |
TT0126 # 05 Y:2014 | 05 | 2014 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,806 | $4,900 | Implemented |
OK0872 # 01 Y:2014 | 01 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,899 | $8,580 | Implemented |