Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
426
matching recommendationsNAICS | 336211 | Motor Vehicle Body Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0367 # 08 Y:2005 | 08 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $11,267 | $14,500 | Not Implemented |
IA0367 # 09 Y:2005 | 09 | 2005 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $8,580 | $14,000 | Not Implemented |
IA0367 # 10 Y:2005 | 10 | 2005 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,781 | $500 | Not Implemented |
IA0367 # 11 Y:2005 | 11 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,202 | $1,640 | Not Implemented |
IA0367 # 12 Y:2005 | 12 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,745 | $28,000 | Not Implemented |
UM0281 # 01 Y:2005 | 01 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,337 | $300 | Implemented |
UM0281 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,591 | $3,891 | Implemented |
UM0281 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,961 | $75 | Implemented |
UM0281 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,214 | $75 | Implemented |
UM0281 # 05 Y:2005 | 05 | 2005 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $125 | $100 | Implemented |
GT0794 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,414 | $30,000 | n/a |
GT0794 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,785 | $3,525 | Not Implemented |
GT0794 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $595 | $765 | Not Implemented |
GT0794 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,306 | $2,046 | Implemented |
GT0794 # 05 Y:2004 | 05 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,022 | $3,380 | Not Implemented |
GT0794 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,490 | $2,500 | Implemented |
GT0794 # 07 Y:2004 | 07 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $729 | $1,500 | Not Implemented |
GT0794 # 08 Y:2004 | 08 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,773 | $4,900 | Not Implemented |
GT0794 # 09 Y:2004 | 09 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,609 | $0 | Implemented |
UM0223 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,160 | $500 | Implemented |
UM0223 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,344 | $958 | Implemented |
UM0223 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,704 | $5,850 | Not Implemented |
UM0223 # 04 Y:2003 | 04 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $23,898 | $3,150 | Not Implemented |
UM0223 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,530 | $3,000 | Implemented |
UM0223 # 06 Y:2003 | 06 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $37,000 | $9,500 | Implemented |