Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0505 # 06 Y:2013 | 06 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,315 | $910 | Implemented |
IA0505 # 05 Y:2013 | 05 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $795 | $200 | Implemented |
IA0505 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,467 | $845 | Implemented |
IA0505 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $319 | $100 | Implemented |
IA0505 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $503 | $50 | Implemented |
WM0008 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,760 | $0 | Not Implemented |
WM0008 # 09 Y:2012 | 09 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,137 | $3,034 | Not Implemented |
WM0008 # 10 Y:2012 | 10 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $840 | $400 | Not Implemented |
WM0008 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,834 | $0 | Not Implemented |
WM0008 # 04 Y:2012 | 04 | 2012 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $40,676 | $83,400 | Not Implemented |
WM0008 # 05 Y:2012 | 05 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,551 | $1,000 | Not Implemented |
WM0008 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $432 | $520 | Not Implemented |
WM0008 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $1,209 | $990 | Not Implemented |
WM0008 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,737 | $0 | Not Implemented |
WM0008 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,802 | $0 | Not Implemented |
WM0002 # 01 Y:2012 | 01 | 2012 | USE POWER DURING OFF-PEAK PERIODS | $56,454 | $0 | Not Implemented |
WM0002 # 07 Y:2012 | 07 | 2012 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,884 | $0 | Implemented |
WM0002 # 06 Y:2012 | 06 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $11,459 | $0 | Not Implemented |
WM0002 # 05 Y:2012 | 05 | 2012 | INSULATE BARE EQUIPMENT | $1,425 | $500 | Not Implemented |
WM0002 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $243 | $30 | Not Implemented |
WM0002 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,844 | $55,770 | Implemented |
WM0002 # 02 Y:2012 | 02 | 2012 | USE PHOTOCELL CONTROLS | $875 | $750 | Not Implemented |
IC0189 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43 | $58 | Implemented |
IC0189 # 07 Y:2011 | 07 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $294 | $0 | Not Implemented |
IC0189 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,263 | $1,142 | Implemented |