Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
82
matching recommendationsNAICS | 3363 | Motor Vehicle Parts Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0429 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $27,312 | $0 | Not Implemented |
NC0429 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,733 | $100 | Implemented |
NC0429 # 04 Y:2011 | 04 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,499 | $5,803 | Not Implemented |
NC0429 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $830 | $2,077 | Not Implemented |
NC0419 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $139 | $517 | Implemented |
NC0419 # 05 Y:2011 | 05 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $873 | $50 | Implemented |
NC0419 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $363 | $100 | Implemented |
NC0419 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $50 | Implemented |
NC0419 # 02 Y:2011 | 02 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,212 | $2,582 | Not Implemented |
NC0419 # 01 Y:2011 | 01 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $967 | $25 | Implemented |
NC0347 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $283 | Implemented |
NC0347 # 01 Y:2006 | 01 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $6,708 | $0 | Implemented |
NC0347 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,347 | $100 | Implemented |
NC0347 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,895 | $3,400 | Implemented |
NC0347 # 04 Y:2006 | 04 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,125 | $22,000 | Implemented |
NC0347 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $95 | $165 | Not Implemented |
NC0347 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,060 | $5,000 | Implemented |
NC0347 # 05 Y:2006 | 05 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,239 | $5,000 | Not Implemented |
NC0290 # 02 Y:2004 | 02 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,371 | $4,079 | Not Implemented |
NC0290 # 03 Y:2004 | 03 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,085 | $5,500 | Not Implemented |
NC0290 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $2,865 | $9,174 | Not Implemented |
NC0290 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,206 | $2,269 | Not Implemented |
NC0290 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $612 | $100 | Implemented |
NC0290 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,346 | $2,533 | Implemented |
NC0290 # 01 Y:2004 | 01 | 2004 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $145,703 | $276,000 | Implemented |